emergency core cooling system 堆芯事故冷却系统 ; 应急堆芯冷却系统
passive emergency core cooling system 非能动堆芯应急冷却系统
core auxiliary cooling system 堆芯辅助冷却系统
core standby cooling system 堆芯备用冷却系统
emergency core cooling injection system 应急堆芯冷却剂注入系统
Reactor Core Isolation Cooling System 炉心隔离冷却系统
core accident cooling system 堆芯事故冷却系统
core emergency cooling system 堆芯应急冷却系统
Based on the PWR best-estimate program RELAP5/MOD3.4,the reactor coolant system and the passive core cooling system of AP1000 were modeled and analyzed. Some key transient parameters were obtained,including RCS pressure,break discharge,cladding temperature,etc.
基于压水堆最佳估算程序RELAP5/MOD3.4,对AP1000的冷却剂系统和非能动堆芯冷却系统进行建模分析,得到了系统压力、破口流量、燃料包壳温度等关键参数的瞬态变化,计算结果与西屋公司采用NOTRUMP程序计算的结果基本一致。
参考来源 - AP1000冷管段小破口失水事故分析·2,447,543篇论文数据,部分数据来源于NoteExpress