两者都是强大的陶立克式结构,风味,虽然这两个纳入离子柱在其内部。
Both are structures with strong Doric flavor, although both incorporate Ionic columns in their interiors.
通过XRD、TEM、FTIR、TG-DTA等多种表征手段分别对有机阴离子柱撑水滑石的晶相结构及其影响因素、晶体形貌、红外性能、热稳定性进行了研究。
The crystal structure and outward appearance, IR property and thermal stability of the organic-anion-pillared hydrotalcites have been studied by XRD, TEM, FTIR and TG-DTA.
研究了有机酸在阴离子交换柱垫片组(日本岛津)上的作用机制。
The mechanism of organic acids on an anion exchange column Shim pack (Shimadzu, Japan) have been studied.
本文研兖了木糖醇、阿糖醇、山梨糖醇在离子交换树脂层析柱上的分离。
The paper discussed the separation of Xylitol, Arabitol and Sorbitol by Ion Exchange Chromatography.
为了消除潜在的干扰物质,可在一个SPE阴离子交换柱上进一步清洗样品。
In order to remove potentially interfering substances, the sample can be further cleaned on an SPE anion exchange cartridge.
实验表明,这种微波放电装置是产生长程均匀放电激光等离子体柱的一种有效方法。
The experiment results show that this microwave discharge design is adequate to excite long uniform plasma column for gas lasers.
带自动进样器的气相色谱-质谱联用仪(GC-MS),分流/不分流进样,可编程的柱箱和可以进行离子选择监测。
Gas Chromatograph-Mass Spectrometer (GC-MS) with an auto-sampler, split/splitless inlet, programmable GC oven, and capable of selective ion monitoring.
最后到达的区域是正柱区,这里,电子和离子具有相等的密度。
Finally the positive column is reached where electrons and ions have equal densities.
方法:样品溶解后,采用固相萃取法去除大部分水溶性大分子,通过离子色谱分离,柱后衍生化-紫外检测器法测定溴酸盐。
Methods: A Solid Phase Extraction was used to purify the dissolved sample. The extracts were separated and detected by ion chromatography post-column derivation with ultraviolet detector.
样品中的镉用强阴离子交换固相萃取柱固相萃取预分离和富集后,用该方法测定,结果令人满意。
Cadmium of sample is primarily separated and concentrated by strong anion exchanging solid phase extraction column, then using this method to determine cadmium, the result is satisfied.
采用实验室土柱法研究了重金属镉离子在非饱和土壤中的迁移规律。
The procedure of heavy metal cadmium ion transport through unsaturated soils was simulated by virtue of laboratory soil column tests.
此工艺需同时使用一强酸性阳离子交换柱和一强碱性阴离子交换柱以除去水中所有离子。
Both a strong acid cation bed and a strong base anion bed are required to remove all of the ions in the water.
系统研究了碱金属、铵离子和烷基胺在磺酸型阳离子交换树脂柱上以有机酸和无机酸为淋洗液的保留行为。
Retention behavior of alkali metals, ammonium ion and alkyl amines on a sulfonic cation-exchange resin column with organic acid and inorganic acid as eluent was studied.
此外,建立了一种原创的基于置换色谱的非均相聚合方法——阳离子交换色谱柱上聚合反应。
In addition, an original heterogeneous polymerization method, based on displacement chromatography, has been tested. We named it "polymerization reaction in cation exchange chromatography".
作者主要探索用离子交换树脂柱析法提纯文蛤提取液中牛磺酸及用吸收光谱法测定牛磺酸的可行性。
This paper is to discuss the feasibility of refining taurine in the extract of Meretrix meretrix by column chromatography and determination of taurine by spectrophotometry.
去离子是使自来水通过离子交换柱除去可离子的矿物质。
Deionization removes ionizable minerals from tap water by passing the water through ion-exchange beds.
采用双柱双氢焰离子化检测器测定空气中的总烃和非甲烷烃。
Using dual column with flame ionization detector to determine total hydrocarbon and non-methane hydrocarbon in air.
用同位素d_2o和KCL作示踪物,在间断灌水的条件下,追踪了D_2O和阴、阳离子在土柱中移动的动态。
Under the conditions of uninterrupted irrigation D_2O and KCL as the tracers traced the kinesis of D_2O, positive and negative ions in the edaphic column.
本文用土柱装置进行了阳离子表面活性剂对粘土截留水中油类影响的动态研究。
Soil columns are used for the dynamic study of the cationic surface activator's effect on clay for intercepting water borne oil.
本文采用双柱在线离子交换预浓缩FIA-ICP系统,建立了水及土壤浸出液中痕量钼的测定方法。
Trace amounts of molybdenum in water and soil extract samples were determined using a dual column on-line ion-exchange preconcentration FIA-ICP system.
研究了用硅胶整体柱和直接电导检测的离子对色谱快速分析高氯酸盐的方法。
Fast analysis of perchlorate was carried out by ion-pair chromatography using a silica-based monolithic column and direct conductivity detection.
讨论了具有抛物线形电流分布的电弧等离子体柱在磁场中的不稳定性问题。
The helical instability problem of an arc plasma column with a parabolic current profile in a magnetic field is discussed.
凝血酶经CM离子交换液相层析柱进一步纯化。
Thrombin was further purified with CM ion-exchange liquid chromatographic column.
根据蛋白质所带电荷的不同而进行分离的一种柱层析技术。层析柱用离子装填。
A type of column chromatography in which proteins are separated according to charge. Column is loaded with ions.
烃类组分采用25%角鲨烷填充色谱柱恒温分离,以氢火焰离子化检测器(FID)检测,峰面积归一化法定量。
Hydrocarbons was separated with a packed - column coated with 25 % squalane at constant temperature, detected by using an FID, and quantified by area normalization method.
研究了在多离子作用下的不同水灰比的混凝土梁与柱的承载力随海水侵蚀循环次数的衰减变化情况。
The change is studied between the bearing capacity of beam and column of concrete with the circulation times of corrosion of sea water.
制备了弱阴离子交换整体柱,并建立了白介素18在该柱上分离纯化的方法。
A weak anion exchange column was prepared and a separation method of interleukin-18 (IL-18) was developed on the column.
本文对柱撑膨润土的制备、成型及其对水中微量重金属离子和有机污染物的吸附进行了研究。
This article studied the synthesis of pillared bentonites, shaping, and the adsorption of trace heavy metals and organic compounds in water.
介绍了用双柱双氢火焰离子化检测器同时进样气相色谱法分析气体样品中非甲烷烃。
Non-methane hydrocarbons in the gas sample are analyzed simultaneously by GC with double columns and double FIDs.
介绍了用双柱双氢火焰离子化检测器同时进样气相色谱法分析气体样品中非甲烷烃。
Non-methane hydrocarbons in the gas sample are analyzed simultaneously by GC with double columns and double FIDs.
应用推荐