The neutral voltage of the three-phase four-leg inverter employed in UPS is desired to be very low.
当三相四桥臂逆变器用于UPS时,要求其中线电压很低。
The abnormal phenomenon of long time higher neutral voltage shift in a substation is analyzed, which is grounded through arc suppression coil.
针对变电所消弧线圈接地系统在正常运行情况下中性点位移电压长时间偏高现象,进行了分析。
Through deduction and analysis, the conclusion can be made: low reactance at the neutral point of transformer has little effect on the switching over-voltage in power systems.
通过计算和分析表明:变压器中性点接入小电抗对系统的操作过电压基本不会产生影响。
In distributions, because of its low-level voltage, its neutral point used to disconnect to the ground in order to improve its reliability.
城市配电网因为其电压等级较低,为了提高系统供电的可靠性,曾广泛采用中性点不接地系统方式。
Due to three-phase capacitance to ground, certain voltage exists between the neutral and the ground for a generator with ungrounded neutral.
对于中性点不直接接地的发电机,由于三相对地电容值存在差异,中性点与地之间存在一定电压。
The principle and structure of the resonance-proof three phase voltage transformer used in the neutral insulation system are discussed. The connection errors brought about in operation are presented.
论述了中性点绝缘系统中采用的三相防谐振电压互感器的原理与结构,并指出了运行中容易发生的接线错误。
This paper proposes a new strategy for balancing the neutral point voltage in the process of the three-level inverter vector controlling.
本文主要研究三电平逆变器在电压空间矢量控制过程中中性点电压平衡的控制方法。
This generator employs three phrase star connections with neutral point, the wire voltage is 400v and the phrase voltage is 230v.
本系列发电机为三相带有中性点的星形接法,线电压为400v,相电压为230v。
In this paper, the effect of the neutral grounded by the low reactance on switching over-voltage in the power system is studied.
文章就中性点小电抗的接入对系统的操作过电压的影响进行了研究。
A method of keeping neutral point potential balanced based on three-level SPWM had been brought forward, which can improve output waveform and decrease the possibility of IGCT's over-voltage.
提出了一种基于三电平spwm调制的中点电压抑制方法,在改善输出波形质量的同时,有效的降低了IGCT过电压的危险。
The on-site test results indicate that energy meter's neutral point virtual connection has a great effect on PT secondary voltage drop.
基于对称分量法,对电能表中性点虚接后的电压互感器二次压降进行了分析,得出了正确接线前后的计量误差变化量。
The paper discusses the low-voltage distribution system earthing and the neutral protection.
现对低压配电系统接地和接零保护进行简要论述。
The selection of shunt reactor parameters and the most withstand voltage calculation of neutral point small reactor are discussed for different compensation modes.
给出了各种补偿方式下并联电抗器参数选择方法和中性点小电抗的最大耐受电压计算方法。
R5 and R8 set a small bias level to reduce the otherwise quite wide neutral deadband caused by the forward voltage drops of the 1n4148's.
R5的和r8设置一个小的偏见水平,以减少,否则相当广泛中立的死所带来的正向电压下降的1n4148的。
This dual path approach means that a single control voltage level signal doesn't have to traverse the full reverse range to get to neutral.
这种双重路径的做法,就是一个单一的控制电压水平,信号没有遍历充分扭转范围去中立。
In both of the cases above, the shift voltage of neutral point often appears. So one does not differ from the other easily, especially for the fundamental frequency ferro-resonance.
且由于二者往往均表现为中性点出现位移电压,尤其是基波谐振更不易与单相接地区分。
In resonant ground systems, both asymmetric fault of high-voltage side and asymmetry of load cause the asymmetry of system electrical source voltage. Then they change neutral displacement voltage.
在谐振接地系统中,系统高压侧不对称故障及负荷的不对称会引起系统电源电势的不对称,从而改变中性点位移电压。
Therefore, the over-voltage caused by the electromagnetic voltage transformer saturation in the system with insulated neutral belongs to shifting over-voltage.
故可得出结论:在中性点绝缘系统中,因电磁式电压互感器饱和引起的过电压现象属于工频位移过电压。
The article introduces voltage unbalance of neutral non-grounding system, analyzes the cause of voltage unbalance. It is valuable on fault analysis in practice.
介绍了中性点不接地系统的几种电压不平衡现象,分析了不平衡现象产生的原因,对于运行中的故障分析具有一定的指导意义。
The recent developments of neutral point ground modes of medium-voltage power network and variety of national related standards are presented.
阐述了中压电网中性点接地方式的近况,国家有关标准的变化,企业应从中吸取有益的东西。
This paper analyzes the neutral point shift of the three-phase voltage regulator used in the experiments.
本文探讨了三相调压器在实验中出现的中性点位移的问题。
A dynamic hysteresis-band current PWM control arithmetic is also designed to control the voltage of the DC bus, which keeps it steady effectively for the voltage of the neutral point of the DC bus.
设计了动态电流滞环pwm控制算法对直流侧电压进行控制,有效地保证了直流侧中点电位的平衡。
But unlike metal, once the voltage is switched off, the plasma rapidly returns to a neutral gas, and the antenna, in effect, disappears.
但和金属不同的是,一旦切断电压,等离子便迅速地变回中性气体,因而其天线作用也就真正地“隐形”了。
In the neutral ungrounded power system, ferroresonance over-voltage due to electromagnetic transformer takes place frequently.
在中性点不接地电网中,频繁发生由电磁式电压互感器引起的铁磁谐振现象。
The problem of neutral-point balance is resolved by changing the amplitude of current reference according to the voltage error of two capacitors.
通过两输出电容电压的偏差改变电流参考给定来实现整流器输出中点平衡。
In selection of neutral points, a concrete analysis of concrete problems should be made. The same operational manners has different forms in different voltage degrees and electric power system wiring.
中性点运行方式的选择要做到具体问题具体分析,同样的运行方式、不同的电压等级、不同的电力系统,接线采用的形式可能不同。
The neutral-point voltage fluctuation of three-level converter is only related to applied modulation method and three-phase current.
三电平变流器的中点电压波动只与变流器采用的调制技术和三相电流有关。
Meanwhile, the topology has voltage-self-balance ability, and therefore, no additional neutral-point-potential balancing circuit is needed.
同时,该拓扑具有电压自平衡能力,无需额外的中点电位平衡电路。
Meanwhile, the topology has voltage-self-balance ability, and therefore, no additional neutral-point-potential balancing circuit is needed.
同时,该拓扑具有电压自平衡能力,无需额外的中点电位平衡电路。
应用推荐