Magnet system composed of main magnetic body, gradient coil and radio frequency coil.
其中磁体系统包括主磁体、梯度线圈和射频线圈。
The headphone features a neodymium magnet system for accurate reproduction and balanced sound.
此款耳机的特色是钕磁铁系统能够精确的再现和平衡声音。
Presently, there are pulsating high gradient magnetic separators with a vertical or horizontal magnet system.
目前有垂直磁系和水平磁系脉动高梯度磁选机。
Superconducting magnet system for MHD propulsion research project has been constructed and tested successfully.
本文简单介绍了磁流体船舶推进用超导磁体系统的研制及实验结果。
The magnetic separation superconducting magnet system has simpler structure, thereby having light weight and small size;
这种超层磁体系统结构更简单,因而不但重量轻、体积小;
The prior electric descaling is resisted by pipeline material and needs to adopt a high power output and an alternate magnet system.
现有的电子除垢会受到管道材料阻抗,并需要采用大功率的输出和交替式磁体系统。
The optimization of binary current leads is one of the key technology in the low temperature superconducting magnet system directly cooled by refrigerator.
对在两级制冷机传导冷却下由高温超导和铜组成的二元电流引线进行热分析。
The present paper summarizes the design, development and test of the D3 superconducting magnet of the toroidal magnet system of the 6D superconducting tokamak.
本文总结了6D超导托卡马克环形磁体系统的D_3超导磁体的设计,研制与试验工作。
The magnet system of the high gradient magnetic separator is the center of the magnetic source providing and supporting, it is the core component of the equipment.
高梯度磁选机的磁系部分是产生和提供磁源的中心,为整机的核心部分。
The power supply is an important part of the superconducting magnet system, it affords both steady current and reliable protection for the superconducting magnet system.
电流源及保护控制系统是超导磁体系统的重要组成部分,其主要任务是为超导磁体系统提供稳定电流并实现可靠的保护控制。
The magnetic Kelvin force generated by a superconducting magnet system can damp the natural convection during crystal growth and thus the crystal quality can be improved.
超导磁体系统产生的磁场力可抑制晶体生长过程中的自然对流,从而提高晶体结晶质量。
The structures and the design of ITER superconducting feeder system, which is an important reference to the feeder design for other superconducting magnet system, are described.
介绍了国际热核试验堆超导馈线系统的结构及设计情况,为同类型超导磁体的馈线设计提供了有益的参考。
The current source is an important section of the superconducting magnet system. It affords both of the steady current and reliable protection for the superconducting magnet system.
电流源保护控制系统是超导磁体系统的重要组成部分,其主要作用是为超导磁体系统提供稳定电流并实现可靠的保护控制。
In this article, a dewar for this superconducting magnet system is mainly described and experimental results about boil-off rate of the LHe under the condition of rotation and vibration is presented.
本文将主要描述该系统的杜瓦部分,并且给出在旋转和振动条件下的液氦挥发实验结果。
The first attempt to accelerate each of two opposing beams of protons to 3.5 TeV apiece failed when a power supply shut down inadvertently and a new magnet-protection system tripped, dumping the beam.
第一次尝试把两个加快的对立的质子束各以3.5兆电子伏特的电压加速时,遭到了失败。只是无意中关闭电源和一个新的磁保护系统跳闸,倾翻了质子束。
Parents, meanwhile, may need a more open mind about relatively unknown private schools — or about magnet schools in the public system.
同时,对于那些不太出名的私立学校—或者公立学校中那些有吸引力的学校,父母的眼界还要更扩大一些。
Using a permanent-magnet generator, the system delivers up to 400 amps of 28-volt DC electric power at low engine speed.
由于使用了永磁体发电机,CMPS系统可以在低功率速度下,提供最高400安培28伏特直流电源。
Due to the large torque coefficient, small torque ripple and ease of control, permanent magnet synchronous motor (PMSM) system has been widely used in many accurate servo control systems.
永磁同步电动机系统具有力矩系数大、力矩波动小以及控制灵活等优点,在许多精密伺服控制系统中得到广泛应用。
Unwinding: Hydraulic lifting unwinding rack, equipped with magnet powder auto tension system.
放卷:气压提升式放卷架、配磁粉自动张力系统。
The system must be cooled to 50 millikelvins to minimize thermal vibrations, which interfere with the cantilever’s magnet-induced displacement signal.
其必须冷却到50微K,以尽可能的减小热振动,因为热振动会干扰悬臂的磁场,而这个磁场又是产生位移信号的关键。
The calculation design system for magnet & magnetic field is a kind of special calculation and analysis software.
磁场计算与磁体设计系统,是一种用于计算永磁体空间磁场分布的专业软件。
By using this system many magnet parameters such as geometrical shape, size and magnetic properties can be designed reasonably.
利用该系统还可以对磁体的几何形状、尺寸、性能进行设计。
Use HPM hybrid permanent magnet motor to energy saving, and in operation by means of a complete set of control system.
使用HPM混合永磁电机要在运行中节能,还要借助于一套完整的控制系统。
Control system is an important part of contactor with permanent magnet actuator and it will influence the characteristic of contactor.
控制系统是永磁机构接触器的重要组成部分,其控制方案的优劣直接影响到整个接触器的性能。
The three-magnet bending system is suitable for linac beam deflection of free-electron-laser facility.
这种结构紧凑的三磁铁偏转系统适用于自由电子激光器的束流传输。
Objective To investigate the simulation and optimization of birdcage coil in the 0.3t Permanent Magnet MRI system.
目的探讨0.3T永磁MRI系统中笼式线圈的计算机模拟和优化。
The meter make of the test system, note setting, magnet electric point setting, shield, control and joint box.
仪表由测量系统,指装置,磁助电接点装置,外壳,调节装置及接线盒等组成。
A doubly achromatic magnetic deflection system with three sector magnet is described.
描述了一个三扇形磁铁消色差磁偏转系统。
This paper presents two-degree-of-freedom robust control for permanent magnet linear servo system of numerically controlled machine tool.
对数控机床直线伺服系统提出二自由度鲁棒控制。
This paper presents two-degree-of-freedom robust control for permanent magnet linear servo system of numerically controlled machine tool.
对数控机床直线伺服系统提出二自由度鲁棒控制。
应用推荐