The paper analyses the requirements for mechanical exhaust tests under different power done in the large space fire test hall.
文章分析了大空间建筑内机械排烟的要求,并在大空间火灾实验厅内进行了不同火源功率下的机械排烟试验。
As the temperature measure system is large and complex in the large space fire test, the factors affecting measurement precision increase.
在大空间火灾实验中,由于测温系统的庞大和复杂,导致影响温度测量的误差因素增多。
The mechanical smoke exhaust experiments with different air-supplement conditions were conducted in a full-scale large space fire experimental hall.
在一个全尺寸的大空间火灾实验厅内,进行了不同补风口位置和补风口面积下的机械排烟试验。
The present paper aims to introduce the authors' investigation and research on the mechanical smoke exhaust efficiency in the large space fire in summer.
采用全尺寸实验对夏季大空间内火灾机械排烟的效率进行了研究。
Full-scale burning test and numerical simulation were carried out to investigate the mechanical exhaust in large space fire with one-side unsymmetrical air supply.
采用全尺寸实验和数值模拟两种方法对大空间火灾单侧不对称补气条件下的机械排烟进行了分析。
Atria and other large volume space do not have the compartmentation that has traditionally been a major contributor of fire protection.
在中庭和其他大空间建筑中没有传统的建筑分隔,这些建筑分隔对于防火保护有重要作用。
Recently, it became a puzzle to design the fire escape system for underground space with large floor areas or huge depth.
近年来,一些大规模、大深度地下空间防火疏散设计逐渐成为工程设计人员所面临的一个难题。
Meanwhile, the large eddy numerical simulation (LES) analysis on the fire process of the narrow and long underground confined space is accomplished based on the experiments.
结合实验完成了狭长式地下受限空间火灾的大涡三维数值模拟分析。
Several fire detection schemes that should be adopted in large space were given and compared.
针对高大空间,给出了几种火灾探测的方案,并进行了比较。
In order to resolve the problems that came from the new fire control system in large space, some projects were put forward, which improved the reliability of early fire detecting and alarming system.
针对大空间新型消防报警系统设计的具体问题,提出了相应的解决方案。大空间新型消防报警系统的实施提高了早期火灾探测和报警的可靠性。
This article introduced the application of performance-based fire-protection design approaches in large space exhibition buildings based on analyzing their fire characteristics.
本文通过分析大空间展览建筑的火灾特性,引入了性能化防火设计方法在这类建筑中的应用。
The fire control design of cargo transferring storeroom is complex and special for large space and denseness goods.
货物中转库空间大,内部堆放货物密集,在消防设计中具有一定的复杂性和特殊性。
Analysis was made for smoke filling process in large space building, and some full scale pool fire tests for comparison were made in USTC large space experimental hall.
分析了烟气在大空间建筑内的充填情况,得到不同火源下的烟气填充计算模型,并在大空间实验厅内进行了全尺寸油池火对比试验。
The paper introduces the working principle, function and characteristics of large-space fire detector and extinguishing system.
本文介绍了大空间内火灾探测器和灭火系统的工作原理、性能及其特点。
Based on the features of high and large space buildings, this paper firstly analyzes the disadvantages of the traditional technology of fire detection and putting out.
本文结合高大空间建筑特点,分析了传统火灾探测与扑救技术所面临的问题。
The rationality of selection of extremely early air sampling detector for automatic fire alarm system of the high and large open space building is discussed.
论述了高大开放式空间建筑火灾自动报警系统选用极早期空气采样探测器的合理性。
The design of automatic fire alarm system for high and large open space buildings is the new and difficult areas for electrical design of modern building electricity design.
摘要高大开放式空间建筑火灾自动报警系统的设计是现代建筑电气设计的新兴和难点领域。
The large-space buildings are overlooked in the currently available design norms on fire control.
现行防火规范未能涵盖大空间建筑。
The large-space buildings are overlooked in the currently available design norms on fire control.
现行防火规范未能涵盖大空间建筑。