本文介绍一种由三维样品调节器、光学系统和离子光学系统组成的激光探针离子源的工作原理与结构设计。
This paper describes the working principle and structure design of a laser probe ion source which is composed of an x-y-z manipulated sample holder, an optical system and an ion optical system.
三种氨基酸修饰玻碳电极表面在中性溶液均呈现荷负电性,对于带负电荷的活性探针离子均具有静电排斥作用。
In neutral condition, three kinds of amino monolayer show electronegative, which has an electrostatic repulsion to the negative REDOX probe.
实验结果表明,赖氨酸分子在电极表面组装形成的单层膜不很致密,对于呈负电性的活性探针离子具有静电排斥作用。
The experiment results indicated that there is a not very compact Lysine monolayer on the surface of glassy carbon electrode, which has an electrostatic repulsion to the negative REDOX probe.
根据探针收集电子流的理论,提出电子流对探针电位的一次微商的最大值对应着等离子体电位。
Based on the theory of electron current collected by probe, that the maximum derivative of electron current with respect to probe potential corresponds with the plasma potential is presented.
利用原子力显微镜、二次离子质谱分析仪和探针,对多晶硅薄膜的高温退火特性进行了实验研究。
An experiment was conducted to study the high-temperature annealing characteristics of polysilicon films using atomic force microscope, secondary ion mass spectroscopy and probe.
扫描离子电导显微镜技术是在纳米尺度进行非导电的生物样品成像的一种新型扫描探针显微镜技术。
As a new kind of scanning probe microscopy, scanning ion conductance microscopy (SICM) is designed for imaging non-conducting biological sample at the nanometer scale.
在离子回旋共振加热(ICRH)实验中用于测量瞬态射频(RF)阻抗的探针列阵常常给出错误的结果。
Probe array used for the measurement of transient RF impedance in ion cyclotron resonance heating (ICRH) experiment often gives erroneous results.
本文讨论了测量离子探针灵敏度的各种方法。
This paper describes the sensitivity measurement of ion microprobe mass analyzer.
报道了自行设计开发的离子探针新软件包数据系统。
The newly developed software package for data processing system in ion microprobe is reported in this paper.
某些技术同样适用于粒子能量分析器和束流探针等离子体电位测量。
Some of these techniques can be applied to beam probes and particle energy analyzers.
电子探针成分分析表明,其颜色是由铜离子引起的,铜的含量越高,颜色就越鲜艳。
Chemical composition analysis by microprobe shows that its colour is related to the content of CuO.
场致发射负离子及其飞行时间谱的获得导致场致发射负离子原子探针的发明。
The acquisition of field emission negative ion and its time-of-flight Spectra (TOPS) brings up to negative ion atom probe invention.
本论文基于分子自组装技术制备了多种形貌的光纤探针和用于水中铜离子检测的组氨酸修饰金电极。
Optical fiber probes with various shapes and gold electrodes modified with histidine for determining copper in water have been fabricated based on self-assembled technology in this dissertation.
本论文由两部分内容组成:新型萘酰亚胺金属离子荧光探针的设计、合成及性能研究和丁二酰亚胺光解的研究。
This dissertation consists of two parts: Study on the naphthlimide fluorescent probes for metal ions and investigation on the photolysis mechanism of succinimides.
本文综述了有机硼化合物在氟离子探针领域的研究进展。
The development of organoboron compounds used as fluoride ion probes are reviewed.
稀土金属离子是一种研究生物大分子体系的有效探针,同时其自身的生物效应也越来越受到人们重视。
Rare earth ions can be used as a kind of effective probe in biomolecular studies, and their biological effects have received increasingly attention nowadays.
本文给出了发射探针和电容探针测量等离子体电位的实验和方法。
Experiments and methods for measuring plasma potential with emissive probe and capacity probe are described.
采用荧光探针法研究了在烷基伯胺和季铵盐阳离子表面活性剂在一水硬铝石表面吸附层结构。
Pyrene fluorescence probe was used to investigate the structure of the adsorbed layer of cationic surfactants primary amines and quaternary amines at the diaspore-water interface.
本文用激光探针测量了砷离子注入硅在CW CO_2激光退火过程中的实时分辨反射率。
The time-resolved optical reflectivity of as ion-implanted silicon during CW CO_2 laser annealing has been measured by using laser probes.
用混沌动力学方法对多道扫描静电探针的离子饱和电流信号进行分析,研究了等离子体尾迹流场。
A plasma wake flow field is studied by analyzing the saturated ionic current of multiple scanning probes with the method of chaos dynamics.
本文利用基于虚拟仪器的朗缪尔双探针系统对电弧离子镀等离子体进行了诊断研究。
The Langmuir double probe system based on Virtual Instrument was used to diagnose arc ion plating plasmas.
探讨了包括离子液体探针试剂的种类、用量、检测波长、流动相比例、流速等对检测效果的影响。
The influence of types and concentration of ionic liquids, detection wavelength, proportion of mobile phase, flow rate on the result of detection were discussed.
文中采用无源探针对由等离子弧梯度电压和等离子鞘层电压构成的等离子反翘(等离子云)电压进行检测。
A non power supply probe was developed to detect the plasma cloud voltage, which consists of plasma arc voltage gradient and plasma sheath voltage.
利用朗缪尔静电双探针诊断了蒸发镀膜装置反应室内等离子体密度及分析其分布规律,并分析了气压和功率对等离子体分布的影响。
The characteristic of spatial distribution of plasma ion density in reaction chamber were diagnosed by a Langmuir double probe, and the effect of Ar pressure and RF power were also investigated.
本文介绍了一种可以测量局部等离子体电子密度的微波共振探针法,并给出了它的测量原理、设计方法和实验结果。
A microwave resonator probe method for diagnosing local plasma electron density is described, and the measurement principle, design method and experiment results are included.
本文基于双曲面形样品针尖,计算了负离子原子探针中负离子的飞行轨迹。
The trajectories of the negative ions in the negative ion atom probe have been calculated for hyperboloidal tip shape.
用双探针技术对生成的氧等离子体进行了诊断测量。
The produced oxygen plasma has been measured by double probe technique.
测量的结果表明,利用单探针测量的主等离子体边缘参数与朗缪尔四探针测量结果基本一致。
The results obtained show that radial profiles of the temperature and the density measured with the single probe are in agreement to those with a four-probe system.
用谐振探针在余辉式等离子体中进行测量,观察到了谐振效应。
A measurement with a resonance probe in the afterglow plasma was carried out and the resonance phenomenon was observed.
用谐振探针在余辉式等离子体中进行测量,观察到了谐振效应。
A measurement with a resonance probe in the afterglow plasma was carried out and the resonance phenomenon was observed.
应用推荐