这些并联的发电机的电流会累积在一起,总电流达到 500安培。
The current from these parallel generators will add up to make a total flow of 500 amperes.
如果给定结两侧的电压就可以求出通过隧道结的总电流。
The total amount of current through the junction can be calculated by giving a fixed voltage at the sides.
有机基质的可生化性对模拟反应器的总电流也有显著影响。
The bio-degradability of the substrate also had influence on the currents.
结果表明:限制钾离子总电流能有效抑制螺旋波和时空混沌;
One is that the spiral wave and spatiotemporal chaos can be effectively suppressed by limiting the total current of potassium.
它可以读出总电流计算马达或泵的运行间隔等等。累加器也可以累计成批称重操作。
This can be used to provide readout of totalized flow, calculate service intervals of motors or pumps, etc. the totalizer can also accumulate batch weighing operations.
而设计加入一个差模EMI滤波器以提升系统电路的功率因数并降低总电流谐波量以符合相关的规范。
The design of input differential-mode (DM) EMI filter for the reduction of total-harmonic-distortion (THD) for line current has been developed in considerations of practical design limitations.
正犹如并联的抽水机同样,这些个并联的发机电所孕育发生的电流将加在一路,以构成100安培的总电流。
Just as with the parallel water pumps, the currents form these parallel generators will add together to make a total flow of 100 amperes.
额定电流和总电阻等参数均在铭牌上标明。
Rated current and the total resistance and other parameters are indicated on the nameplate.
仿真结果表明,电机转速比是影响交交变频轧机系统网侧基波功率因数与电流总畸变率的关键原因。
The simulation results show that the speed ratio of the motor mostly affects the total harmonic distortion of the current and the displacement power factor.
一种方案采用以极化电流为未知函数的积分方程,另一种方案采用以总电场为未知函数的积分方程。
One of the schemes adopts the integral equation with equivalent current as an unknown function, whereas the other USES the integral equation with total electric field as an unknown function.
此时间为从跳闸线圈受电到主触头电弧电流开断为止的总时间。
This is the total time from energizing the trip coil until the interruption of current on the primary arcing contacts.
实验结果表明,应用该电路拓扑的实验装置,其功率因数较高,输入电流的总谐波畸变较低,输出电压纹波小,而且整个装置的效率也比较高。
Experiment result showed, the topology can make the device get to high Power Factor (PF), low Total Harmonic Distortion (THD) of input current, low ripple of output voltage, and high efficiency.
采用两路结构相同的最大电流选择电路实现输入级总跨导的恒定。
The constant gm of input stage is achieved by two identical maximum current selection circuits.
所以输出电压可以用来度量输入电流,总的灵敏度由反馈电阻器(RF)决定。
Thus, the output voltage is a measure of input current, and overall sensitivity is determined by the feedback resistor RF).
然后使用不同的调制方法对逆变器进行调制,并比较两种方法的优缺点,包括输出电压以及电流的总的谐波失真比率。
Two different modulation methods are used to modulate the inverter and their advantages and disadvantages are compared, including total harmonic distortion (THD) of voltage and current.
然后把电流从变压器输入建筑物的总输入点。这个输入点叫做供电端点或配电端点。
Electricity is then carried from the transformer to a main entry point for the building. This entry point is called the service point, or the distribution point.
模拟结果表明,设计的两种新多米诺电路在同样的噪声容限下有效地降低了动态功耗,减小了总的漏电流,同时提高了工作速度。
The simulation results show that the proposed circuits effectively lower the active power, reduce the total leakage current, and enhance speed under similar noise immunity conditions.
确保插在电源器上的电源线范围数不要超过额定数,也不要超过总的额定电流。
Ensure that the total ampere ratings on all units plugged into the extension cord is not above the cord's rating.
根据测出的电流波形求解出总电量,计算出电流效率大于100%,对此试验现象也进行了初步的分析。
The calculation results show that the electric current′s efficiency is above 100%, and the phenomenon has been analyzed.
励磁电流引线是超导装置的重要组成部分,其漏热量往往占低温容器总漏热量的主要部分,是决定系统运行成本的重要因素。
Current lead is an important part of a cryogenic device, and it is also one of the main sources of heat loss of the system.
给出了一定分布电流下,整数倍半波天线辐射场的平均能流密度、辐射总功率及辐射电阻。
The article presents the average energy density, the total radiant power and the radiant resistance of the integral multiple semi-wave antenna with the electrical current of certain distribution.
建立了包括电流控制电路、功率驱动电路以及五相混合式步进电动机在内的恒频斩波恒总流驱动系统的完整的数学模型;
Mathematical model of the system, included the current control circuit, power driving circuit and five-phase hybrid stepping motor is established.
根据导出方程(2)的步骤,找出从材料2到材料1的电流的相似表达式。对总隧穿电流有。
Following the route that has led to Eq. (2), find a similar expression for the current from material 2 into the material 1. For the total tunneling current obtain.
较系统地研究了时间、电流密度、料液初始浓度等因素对葡聚糖-聚乙二醇-水体系中的苯丙氨酸上下相浓度比、萃取率、总传质量以及电流效率的影响。
The influences of time, current intensity, initial solute concentration on two-phase concentration ratio, recovery ratio, total mass flux, and electric current efficiency was discussed.
大部分之前的概念的基本问题在于,在通过漏电电流及配位方面,人们总希望固态断路器能像传统的机电断路器那样工作。
A fundamental problem with most prior concepts is the desire to have the solid state breaker behave like a traditional electromechanical breaker in terms of fault let-through current and coordination.
在这种新的逆变器开关控制策略中建立多目标优化函数,既使得电压型逆变电路输出电流波形总谐波畸变率尽量小,同时又能减小逆变过程的电力电子开关损耗。
In this control law multi-object function is created, which enables a voltage-source type inverter to produce a near standard sine wave with a minimum switching loss.
该样机在实验中测得输入电流总谐波畸变率(THD)为4.26%,功率因数为0.998,达到了预期的设计效果。
Themeasured input current THD is 4.26%. Power Factor attains 0.998. Theprototype realizes the expectation.
该样机在实验中测得输入电流总谐波畸变率(THD)为4.26%,功率因数为0.998,达到了预期的设计效果。
Themeasured input current THD is 4.26%. Power Factor attains 0.998. Theprototype realizes the expectation.
应用推荐