On-line PD monitoring of power transformer is Presently the research hotspot in the area of high voltage insulation measurement and diagnosis.
电力变压器局部放电在线监测是当前高电压绝缘检测与诊断领域研究的热点课题。
On-line PD monitoring of power transformer is presently the research hotspot in the area of high voltage insulation measurement and diagnosis.
变压器局部放电在线监测是高电压绝缘检测与诊断领域研究的热点课题。
Large power transformer partial discharge on-line monitoring technology is a hot topic in high voltage insulation detection and diagnosis domain.
大型电力变压器的局部放电在线监测技术是高电压绝缘检测与诊断领域研究的热门课题。
The feature extraction of partial discharge signal of transformer is the front research project in online monitoring and diagnosing high voltage insulation failure.
大型电力变压器局部放电信号的特征提取是电气设备绝缘在线监测及故障诊断技术领域的前沿研究课题。
This paper introduces the hardware and software of microprocessor voltage insulation supervising equipment of DC system in transformer substation and effection of using it.
介绍变电站微机型直流系统电压绝缘监察装置的硬件、软件框图及应用效果。
This paper introduces several safety protection devices, such as TJB high-voltage cable couplers, high-voltage insulation, ground continuity monitor and insulation monitor.
介绍其中的几项保护装置,如TJB高压电缆快速接头、高压电缆绝缘及接地线连续保护装置、低压母线绝缘监视装置在TBM上的应用。
The fuzzy logic-neural network is used to analyze the tendency of insulation parameter change of HV(High Voltage) electric equipment.
提出了利用模糊逻辑-神经网络分析高压电气设备绝缘参数变化趋势的方法。
ZJC-50KV controlled by computer, through the man-machine dialogue mode, the voltage breakdown insulation, power frequency withstand voltage test.
50KV采用计算机控制,通过人机对话方式,完成对绝缘介质的工频电压击穿,工频耐压试验。
The Insulation level between poles and enclosure is important for high voltage shunt capacitors to increase the operation reliability.
高压并联电容器极对壳绝缘水平是保证其在电网安全运行的重要参数。
Repair lower voltage equipments and power transmission includes tank farm pumps, main workshop and fire fighting water pump. Regular test motor and distribution cabinet insulation.
维修低压设备和给低压设备停送电,包括罐区的泵、主车间泵和消防泵泵。定期测试电机和配电柜的绝缘。
The insulation capability of High Voltage Storage Capacitor (HVSC), which is the kernel of impulse power, determines the service reliability of impulse power system.
高压储能电容器作为脉冲功率系统的核心储能元件,其绝缘性能直接关系到脉冲功率系统工作可靠性。
This high voltage can initiate a second fault at the weakest insulation point in the system.
这高的电压能在系统中最弱的绝缘点开始一种第二种过失。
Using computer control, man-machine dialogue mode, the completion of the power frequency voltage breakdown of insulation media, power frequency withstand voltage test.
采用计算机控制,过人机对话方式,完成对、绝缘介质的工频电压击穿,工频耐压试验。
While fulfilling the qualification of test technique, it can test the voltage, current, time and insulation impedance for 13 kinds of time mechanisms, and has replaced 13 primary test equipments.
在满足测试技术指标的前提下,能够完成对13种定时机构产品的电压、电流、时间和绝缘阻抗等性能的测试,取代了原有的13个不同的测试仪器。
The principle, main design point and no load voltage ratio calculation method of resin insulation dry-type grounding transformer are introduced.
介绍了树脂绝缘干式接地变压器的工作原理、设计要点及空载电压比的计算方法。
A test method for insulation between coils of electrical equipment based on directly impulse voltage are presented.
本文提出了一种基于直接冲击电压对电器绕组匝间绝缘的试验方法。
The principle and structure of the resonance-proof three phase voltage transformer used in the neutral insulation system are discussed. The connection errors brought about in operation are presented.
论述了中性点绝缘系统中采用的三相防谐振电压互感器的原理与结构,并指出了运行中容易发生的接线错误。
High voltage is applied between the two parts across the insulation being tested, such as the primary circuit and metal enclosure of the equipment under test (EUT).
高压施加于被试的两个相互绝缘的部件之间,例如被试设备的主电路与其金属外壳。
Rated voltage lines higher insulation to the longer ionization time.
线路额定电压越高,绝缘去电离时间越长。
These factors including distribution of circuit breakers closing Angle, rated voltage of MOA and the insulation level of transmission line are considered.
同时还研究了断路器合闸相位角分布规律、MOA的额定电压、线路绝缘水平等因素的影响。
Aim at the higher level of dynamic insulation design, a whole optimized design method for high voltage vacuum interrupters is proposed.
本文以动态绝缘为设计目标,提出高电压真空灭弧室的全程优化设计方法。
The initial discharge voltage using pressured air as insulation medium has different characters under diverse pressures.
空气绝缘起始放电电压在不同压力下表现出不同的特征。
The testing of insulation resistance, dielectrics voltage-resistance and contact resistance is essential for the connector to reliably operate.
绝缘电阻、介质耐压和接触电阻检验是保证电连接器正常可靠地工作的最基本的常规检验项目。
In the paper the influences of altitude and atmosphere condition on external insulation test voltage are introduced, and the effect mechanisms are analyzed respectively.
介绍了海拔高度和大气条件对高压产品外绝缘试验电压的影响及影响机理。
The paper presents modern transducer-fed synchronous motors voltage lever, insulation and ventilation, which give a reference for electrical engineer.
本文深入论述了现代变频同步电动机的电压等级、绝缘结构和通风冷却,以供电机工程人员设计参考。
Insulation resistance is used to describe the isolation performance of high voltage system of electric vehicle.
提出用绝缘电阻描述电动汽车高压电气系统的绝缘性能。
There already have some outcomes in studies of on-line monitoring of the running condition and the insulation condition of the high voltage equipments in power system.
电力高压设备运行状态在线监测和绝缘状态在线监测的研究在电力系统中已经取得一定的研究成果。
Partial discharge pattern recognition is considered as an effective tool for insulation fault diagnosis on high voltage electric equipment.
局部放电模式识别是一种高电压设备绝缘故障诊断的有效方法。
We decide the cross and span clearance by over-voltage times and electrical insulation strength (air spacing) from the system major in places that the public not easy to arrive.
再根据系统确定的操作过电压倍数及电气绝缘强度(空气间隙)来确定在人不宜到达地方的交叉跨越距离;
We decide the cross and span clearance by over-voltage times and electrical insulation strength (air spacing) from the system major in places that the public not easy to arrive.
再根据系统确定的操作过电压倍数及电气绝缘强度(空气间隙)来确定在人不宜到达地方的交叉跨越距离;