A transformer ratio bridge verification apparatus is introduced in this paper.
变压比电桥检定装置是检定变压比电桥的专用检定装置。
This article represented the necessity of applying current converter and deduced in detail the calculation method of current converter's transformer ratio.
阐述了采用电流变换器的必要性,并详细地推导了电流变换器变流比的计算方法。
The voltage ratio is one of important parameters of transformer .
牵引变压器的选择是人们长期关心的问题之一。
In recent years, the ratio of the transformer faults caused by the winding deformation directly or indirectly remains very high.
近年来,由于变压器绕组变形直接或间接导致的变压器损坏事故居高不下。
Compensating reactor in a Capacitive Voltage Transformer (CVT) influences not on-ly its ratio error, but also the rated output capacity.
电容式电压互感器(CVT)的补偿电抗器不但影响电压比的准确度,而且还影响它的额定容量。
The development of a ratio tester for current transformer is introduced.
介绍了一种可用于检测电流互感器变比的测试仪。
The principle, main design point and no load voltage ratio calculation method of resin insulation dry-type grounding transformer are introduced.
介绍了树脂绝缘干式接地变压器的工作原理、设计要点及空载电压比的计算方法。
Aerospace series - elements of electrical and optical connection - Test methods - Part 704: electrical elements - Measurement of turns ratio on a transformer used in a coupler.
航空航天系列。电气及光学连接件。试验方法。第704部分:电气件。耦合器用变压器的匝数比测量。
In this paper, a transformer tap position tracing estimation algorithm based on turn ratio changing detection is proposed.
本文提出一种基于变比变化检测的变压器抽头位置跟踪估计算法。
The transformation ratio of the original current transformer (CT) on the transformer HV side was so large that a parameter for the differential protection software exceeded its settable scope.
因变压器高压侧的电流互感器选择变比过大,以致超出差动保护软件的参数设置的范围。
It is a new current ratio standard after the zero flux current transformer, two stage current transformer and current comparator.
它是继零磁通电流互感器、双级电流互感器和电流比较仪之后的又一种新型的电流比例标准。
Please specify the current transformer model name, transformation ratio, accuracy class, rated burden, required installation method, when placing a purchaseder.
请注明电流互感器型号、额定电流比、准确度等级、额定容量及安装方式等。
Based on the analysis of the differential protection of the double winding transformer, the paper presents a simplified ratio restraint algorithms for the three phase, three winding transformer.
在分析双绕组变压器的差动保护算法的基础上,提出了适用于三相三绕组变压器的比率制动式算法,并对判据进行了简化。
Other output voltages are possible by adjusting the transformer turns ratio and value of Zener diode VR2.
其它输出电压是可能的,经过调整变压器匝数比齐纳二极管VR2和价值。
Through the analysis and research for the dissolved gas in transformer oil, the "non-code ratio method" is given to analyse and judge transformer fault.
通过对实际故障变压器油中溶解气体的分析研究,提出了用“无编码比值法”分析和判断变压器故障性质的诊断方法。
The voltage linear addition characteristic of the fractional-turn ratio pulse transformer was researched with low voltage experiments.
实验验证了分数比脉冲变压器的电压线性叠加性。
A transformer-ratio arm bridge with three terminals is adopted as its measuring circuit to eliminate the influence of electrode edges and exterior interference.
相应地,它的测量电路采用具有三个输入端的变压器电桥,从而免除了电极边缘和外界干扰的影响。
Load tap switch is the central contrivance in load-ratio voltage regulation of transformer.
有载分接开关是变压器有载调压的主要装置。
The traditional theory of tap change of the load-ratio transformer which has not taken the ferromagnetic characteristic into account is a special example of the theory presented in this paper.
在变压器铁磁特性不明显的情况下推导出的传统有载调压变压器无暂态切换理论只是文中理论中的一个特例。
A method for reducing ratio difference and Angle difference of micro-transformer of current and micro-transformer of voltage is forward.
提出了减小微型电流互感器和电压互感器的比差和角差的方法。
It is showed that this transformer has the advantages of boosting, rejecting the negative sequence current, increasing the output capacity and raising the capacity utilization ratio.
结果表明,该变压器具有增压、抑制负序电流、增大输出容量和提高容量利用率等优点。
Through the drive circuit design of the new hydraulic transformer, it is concluded that the transmission ratio has multi-level changes due to the combination of each sub motor working mode.
通过设计单泵多马达液压变速器的传动回路,得出多马达中各个子马达之间工作方式的组合可以使变速器传动比有多级变化。
The output voltage is easily set by two external resistors and the transformer turns ratio.
输出电压非常容易由两个外部电阻器和变压器匝数比设定。
The transmission ratio of manual variable single-pump single-motor hydraulic transformer is not accurate. To avoid the problem, the single-pump multi-motors hydraulic transformer is proposed.
针对单泵单马达液压变速器手动变量传动比不准确的问题,提出了单泵多马达液压变速器。
The transmission ratio of manual variable single-pump single-motor hydraulic transformer is not accurate. To avoid the problem, the single-pump multi-motors hydraulic transformer is proposed.
针对单泵单马达液压变速器手动变量传动比不准确的问题,提出了单泵多马达液压变速器。
应用推荐