• With this connection method, the picoammeter reads a negative current.

    采用这种连接方法时,皮安计读出的电流为负值

    youdao

  • Note that before the capacitor is switched to the picoammeter, the capacitor is connected to circuit LO.

    注意电容器切换皮安计之前,它是被连接电路lo的。

    youdao

  • Note the top electrode is guarded, so that only current flowing across the insulator is measured by the picoammeter.

    注意顶部电极接保护所以只有流经绝缘体表面电流才为皮安计所测量

    youdao

  • If this is the case, a simple coaxial vacuum feedthrough can be used to make connections from the collector to the picoammeter.

    这种情况下,可以使用简单真空同轴接头进行收集电极皮安连接

    youdao

  • The voltage across RL1 is the picoammeter voltage burden, normally less than one millivolt, so the resulting current will be quite small.

    RL1电压皮安计的输入端压降,通常小于1mV,所以产生电流相当小的。

    youdao

  • A basic approach to high speed measurements is to minimize stray shunting capacitance through careful mechanical design of the picoammeter.

    实现高速测量基本方法仔细地进行皮安表机械设计尽量减少寄生并联电容

    youdao

  • The picoammeter reads the current at the last dynode, which is equal to the anode current minus the current flowing to the previous dynode.

    皮安最后一个倍增管电极处读取电流,此电流等于阳极电流减去流过前一个倍增管电极的电流。

    youdao

  • Ir measurements often involve multiple conductors, so a switching system is often required to switch the picoammeter and the source to all the conductors in the test circuit.

    由于IR测量往往涉及到导线所以通常需要切换系统皮安切换至测试电路中的所有导线。

    youdao

  • Note that when none of the channels on the Model 7158 card are energized, terminals 2 and 4 are connected to the LO of the picoammeter (pA), which electrically is the guard terminal.

    注意7158型开关卡没有通道被激励时,端子24连接皮安计(pALO端子的,电气上保护端子

    youdao

  • Picoammeter amplifier gain can be changed as in the voltmeter circuit by using the combination shown in Figure 1-11.

    电压表电路一样,可以使用如图1 - 11所示组合电路来改变皮安放大器增益

    youdao

  • A picoammeter is an ammeter built along the lines of the ammeter function of an electrometer.

    皮安安培个门类,其实质上是静电计安培表功能的延续。

    youdao

  • To make the measurement, a constant voltage is applied for a predefined period, usually 60 seconds, and the resulting current is measured with a picoammeter or electrometer.

    为了进行测量,在预定时间(通常为60秒钟)内,样品施加恒定电压然后皮安静电计测量产生电流

    youdao

  • The measured current is usually quite small, so a picoammeter or electrometer is often required to make the measurement.

    得的电流通常非常因此往往需要使用皮安静电计进行测量

    youdao

  • Figure 4-16 shows a Model 6485 Picoammeter measuring the current from the ion collector, which is operating at ground potential.

    4 -16出6485型皮安离子收集电极测量电流的情况,这时仪器工作地电位。

    youdao

  • Applications such as measuring light with a photomultiplier tube generally require the use of a picoammeter due to the low current levels involved.

    由于测量电流非常弱,所以光电倍增测量应用工作通常需要使用皮安计。

    youdao

  • Since the voltage burden of the electrometer ammeter or picoammeter is less than 1mV, the diodes won't conduct.

    由于静电计安培计皮安输入端小于1mV两个二极管不会通。

    youdao

  • Since the voltage burden of the electrometer ammeter or picoammeter is less than 1mV, the diodes won't conduct.

    由于静电计安培计皮安输入端小于1mV两个二极管不会通。

    youdao

$firstVoiceSent
- 来自原声例句
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定