• Can reliably determine, within the community and bounds detection ma level and zero-sequence current phase short circuit fault current, automatic removal of single-phase ground fault and phase fault.

    能可靠判断、检测界内与界外毫安级零序电流及相间短路故障电流,实现自动切除单相接地故障和相间短路故障。

    youdao

  • On this basis, the influences to unbalance current of line tower type, wire parameters and phase sequence arrange are analyzed.

    在此基础上分析线路塔型、导线参数、相序排列等因素对不平衡电流的影响。

    youdao

  • According to the feature of distribution network structure, a practical short circuit calculation method based on fault current compensation and actual phase sequence presentation is put forward.

    根据配电网的结构特点,提出了一种基于故障补偿方法与实际相序表示方法相结合的配电网短路电流实用计算方法。

    youdao

  • Zero-sequence current criterion, negative sequence current criterion and phase current variation can be used to improve the performance of breaker failure protection for ACF sub-bank.

    针对单纯采用相电流判据的不足之处,本文提出增加零序电流、负序电流及电流变化量判据,以有效地避免保护误动或者拒动。

    youdao

  • Experimental results prove the proposed control method can compensate the harmonic, negative sequence and zero sequence current components in the three phase four wire.

    实验结果表明,该装置可对三相四线制系统中的谐波、负序、零序等电流分量进行补偿。

    youdao

  • In the paper, the reduced single phase short-circuit current equation expressing as positive sequence impi dance only is showed.

    文中还提出了低压系统中只用正序阻抗表达的单相短路电流的简化计算公式。

    youdao

  • The phase comparison error is the primary factor leading to mistaken action in the selective leakage protective system of underground LV networks based on zero sequence current direction.

    在基于零序电流方向原理的矿井低压电网选择性漏电保护中,比相误差是导致保护误动的主要因素。

    youdao

  • Type of fault, phase sequence, value of faulty current and breaking action time will be indicated on the intelligent controller promptly if breaker turns off because of faults.

    断路器遇故障分断后,智能控制器能显示出故障类别、故障相序及故障电流值、分断动作时间值。

    youdao

  • The fault phase selectors, including the phase current difference suddenly-change and the sequence current, may misoperate in some cross country faults and conversion faults.

    研究表明相电流差突变量、稳态电流序分量等选相元件在发生某些跨线及转换性故障时会误选相。

    youdao

  • The properties and selection of the zero-phase sequence current transformer core and tripper for GFCI are in detail described.

    详细叙述了漏电开关零序电流互感器及其铁芯,脱扣器的工作特性、材料选用。

    youdao

  • At the time of failure, no matter what kind of start state of voltage phase, the zero-sequence transient current has the characteristic of inverse phase.

    在故障时刻,无论故障相电压的相位处在何种初始状态下,都有零序电流反向的特征。

    youdao

  • Generalized integrator was used to realize static error free tracking control of positive and negative sequence current under two-phase static coordinate.

    并采用广义积分器原理实现对三相电流在两相静止坐标下的控制,实现了正负序电流的无静差跟踪控制。

    youdao

  • Active power filter can compensate current components which include distortion and negative sequence current components when it is used in unbalanced three-phase circuit.

    电力有源滤波器能动态补偿不对称三相电路的畸变电流、负序电流分量。

    youdao

  • It can be combined with a set of transformer main protection by combining negative-phase sequence current sudden-change starting element.

    它也可与负序电流突变量起动元件配合,构成一套变压器主保护。

    youdao

  • This paper analyzes the phase selection theories of sequence current, the current break variable and the compensation voltage.

    分析了反映序电流、电流突变量和补偿电压的选相原理,提出了当电压互感器断线时为防止误动应闭锁补偿电压选相。

    youdao

  • The unbalanced degrees of current in primary winding under different load conditions are discussed, which are based on the general expressions of negative phase sequence current.

    结合负序电流的通用表达式,讨论了在不同负荷条件下的原边电流不平衡度。

    youdao

  • By analyzing the zero-sequence full current for single-phase grounding fault in isolated neutral distribution network, a new approach to determine the faulty transmission line is obtained.

    通过对中性点不接地配电网单相接地故障时零序全电流的分析,得出了利用零序全电流的大小和方向进行故障选线的新方法。

    youdao

  • The power of the protector is supplied by itself from the ct. Based on thermal cumulate principles, a rapid and high precision inverse-time phase-sequence over-current protection is implemented.

    该保护装置自具电源,基于热量累积原理实现快速高精度相电流反时限保护方法,实现对相电流和零序电流三段式保护。

    youdao

  • In this paper, the instantaneous model of zero-sequence circulating current between parallel three-phase inverters with three-pole reactors and three-pole transformers is established.

    该文基于三磁柱变压器及三磁柱电感的动态方程建立了带三磁柱电感及三磁柱变压器的三相逆变器瞬时零序分量模型。

    youdao

  • In this paper, the instantaneous model of zero-sequence circulating current between parallel three-phase inverters with three-pole reactors and three-pole transformers is established.

    该文基于三磁柱变压器及三磁柱电感的动态方程建立了带三磁柱电感及三磁柱变压器的三相逆变器瞬时零序分量模型。

    youdao

$firstVoiceSent
- 来自原声例句
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定