Automatic control of optical calibration instrument is a development direction for high accuracy optical regulation and measuring.
光学标定装置的自动控制是高精度光学测量的发展趋势。
Work closely with manufacture process and NPI engineer to architect, define and deliver optical characterization equipment and various test and calibration fixtures.
密切关注制造工艺和新产品工程师,以便架构,界定和传输光学特性设备和各项测试及校准装置。
Work closely with optical, mechanical and factory test team to bring up production line test and calibration stations.
与光学,机械和出厂测试团队密切合作,以便建立生产线测试与校准站点。
The actual accuracy of an optical measurement system is due to the calibration accuracy. The calibration methods should possess the property of convenience and dependability.
线结构光的标定精度直接决定了测量系统的实际测量精度,而标定方法又直接影响着测量系统使用的方便性和可靠性。
The actual accuracy is due to the calibration accuracy. Calibration methods affect the convenience and dependability of an optical measurement system directly.
系统的标定精度直接决定了系统的实际使用精度,而标定方法又直接影响着视觉测量系统的使用方便性和可靠性。
New method of wavelength accuracy calibration in Optical Spectrum Analyzer is introduced, its principle and implementation are described.
本文介绍了光谱分析仪波长准确度校准的一种新方法,详细阐述了其原理及具体实现。
The optical system, optoelectronic detector, circuitry and calibration technology of prism spectroscopic chromo-thermometer are introduced in detail.
详细介绍了棱镜分光比色温度计的光路系统、光电检测器、电路及其标定技术。
The application of the least square polynomial fit method in the wavelength calibration of the Optical multichannel analyzer with a CCD detector is investigated.
研究了最小二乘拟合方法在CCD型光学多通道分析仪波长标定中的应用。
The micro Angle error between optical coordinate and mechanical datum coordinate of robot vision instrument due to mechanical assembly can be corrected by high accuracy calibration.
机器人视觉仪器由于机械安装引起的光学坐标系与机械基准坐标系之间的微小的角度误差可以通过高精度标定修正。
The optical system, optoelectronic detector, circuitry and calibration technology of prism spectroscopic chromo-thermometer are introduced in detail. The major specifications are given also.
详细介绍了棱镜分光比色温度计的光路系统、光电检测器、电路及其标定技术。文末给出了整机主要技术指标。
Combining with local calibration, the distortion error of the optical system in the camera is corrected.
结合局部标定法,对摄象机光学系统的畸变误差进行校正。
In this paper, the hardware structure and software flow for a portable optical power meter are described, and a method of calibration of this instrument and its measured performance are presented.
介绍了一种便携式光纤功率计设计的硬件结构和软件流程,给出了其标定方法和实测性能指标。
A blackbody furnace of heat-pipe surface source with large aperture was developed for the calibration of infrared image optical systems.
针对红外成像光学系统校正,研制了大口径热管面源黑体炉。
The results of highly accurate optical radiation calibration of cryogenic radiometer have been compared between year of 1999 and 2003.
对1999年和2003年采用不同测量光路情况下可见光波段低温辐射计高精度光辐射定标测量结果及其不确定度进行了比较。
Analog optical colorimeter is used to calibrate correcting filter so as to make it meet Luther condition. However, the calibration precision of the filter is influenced by many factors.
光学模拟测色仪采用校正滤色器使仪器满足卢瑟条件,校正滤色器的精度受多种因素的影响。
This paper covers the calibration method of tungsten-rhenium thermocouples using an optical pyromer as standtard instrument .
本文论述用光学高温计分度钨铼热电偶的方法及其测量不确定度。
In order to realize measurement of aerosol mass concentration in real time by optical particle counter, the calibration method of the instrument was studied.
为了实现光学粒子计数器系统实时精确地测量悬浮颗粒物的质量浓度,对该系统的标定方法进行了研究。
On the basis of discussion of human body motion capture, the key techniques of optical motion capture are introduced, including camera calibration, marker tracking and 3d reconstruction.
在论述了几种方式的人体运动捕捉的基础上,介绍了光学运动捕捉的关键技术,包括摄像机标定、标记点跟踪和三维重建技术。
Automatic zero calibration with ambient air on every start of the system, optical and acoustical signal after finishing of calibration.
开启系统时,仪器会自动进行零校准。校准完毕后会出现光学和声学信号。
But the alignment and calibration of the optical axis and the electric axis of phased array radar demands high perpendicular accuracy of the optical axis to the array plane.
而相控阵雷达光电轴的标定与校准则要求光轴与阵面较高的垂直精度。
The third step, a new method of high-precision calibration with grating grooves is presented for the optical imaging system.
再者,提出了一种新的使用光栅刻线进行成像系统精度标定的方法。
The working principle of 3d scanning with structured light and the system calibration of ATOS optical scanner are introduced.
介绍了ATOS流动式光学扫描仪的结构光三维扫描法工作原理和系统标定方法。
A calibration method for optical fiber loss testing instrument has been put forward for the metrological verification.
本文从计量检定角度提出一种光纤损耗测试仪的校准方法。
In this paper, we present a new calibration scheme for optical tweezers including stiffness and position calibrations.
本文中,我们给出了一种标定光镊的新方法,可以同时用来标定光镊的刚度和位置。
The trap based filter radiometer is a key unit of new optical radiometric standard detectors, and has potential applications in radiometric calibration of field, air borne and space borne sensors.
基于滤光片辐射计的新型光辐射标准探测器在野外、机载和星上高精度辐射定标中具有广阔的应用前景。
Marine optical buoy is of important value in terms of calibration and validation of ocean color remote sensing, scientific observation, coastal environment monitoring, etc.
海洋光学浮标在水色遥感现场辐射定标和数据真实性检验、海洋科学观测、近海海洋环境监测等方面有重要应用价值。
In LBRCF, standard radiation, reference radiation and the radiation under calibration are coaxial by optical deflection, and the use of large-scale sliding tables is therefore avoided.
校准装置内的标准辐射,参考辐射和待测辐射由光学偏转方式进行同轴,使装置避免了大型导轨平台的使用。
An algorithm for the resection of imagery along the optical axis is presented to implement both of the camera calibration and resection at the same time.
提出了一种沿主光轴方向影像的单像空间后方交会方法,实现了相机检校和空间后方交会的同时进行。
Calibration methods are provided for determining servo parameters to enhance an optical drive in reading and writing a blank optical disc.
本发明提供多种调整方法来决定伺服参数,以改进光驱读取或写入空白光盘时的状况。
Calibration methods are provided for determining servo parameters to enhance an optical drive in reading and writing a blank optical disc.
本发明提供多种调整方法来决定伺服参数,以改进光驱读取或写入空白光盘时的状况。
应用推荐