Another consideration when measuring voltages from high resistance sources is the input bias current of the voltmeter.
在测量高电阻源时要考虑的另一个问题是电压表的输入偏置电流。
Although input bias current is a common source of this type of error, currents generated by external circuits can also result in errors due to voltage drops across the source resistance.
虽然输入偏置电流是这种误差的常见来源,但是外电路产生的电流在源电阻上形成的电压降也能引起误差。
The input bias current flows at the instrument input due to internal instrument circuitry and the internal bias voltage.
仪器内部电路和内部的偏移电压会在仪器的输入端引起输入偏置电流。
As shown in Figure 2-2, the input bias current (IBIAS) develops an error voltage across the source resistance (RS).
如图2 - 2所示,输入偏置电流(IBIAS)在源电阻(RS)上产生了误差电压。
Again, consider using AMPLIFIERs that exhibit a smooth input bias current transition throughout the applied input common-mode voltage.
再者,所用的放大器也要考虑在加到输入端的整个共模电压(范围内)输入偏置电流转换保持平滑。
Otherwise, the sensor's capacitance and the amplifier's input-bias-current resistors impose a phase shift on the signal you apply to the instrumentation amplifier.
否则,传感器电容和放大器的输入偏置电流电阻,对仪表放大器的信号施加相位偏移。
Otherwise, the sensor's capacitance and the amplifier's input-bias-current resistors impose a phase shift on the signal you apply to the instrumentation amplifier.
否则,传感器电容和放大器的输入偏置电流电阻,对仪表放大器的信号施加相位偏移。
应用推荐