The optimization of Initial Temperature Difference (ITD) is the relatively key part in the process of the design of the direct air cooling power station.
初始换热温差ITD值的优化是直接空冷电站设计过程中较为关键的部分,关系到整个电站设计是否经济、合理。
Because a direct air-cooled condenser consists of several direct air cooling units, studies on these units have great significances.
直接空冷凝汽器由多个直接空冷单元组成,因此,对直接空冷凝汽器单元的研究具有重要的意义。
Because a direct air-cooled condenser consists of several direct air cooling units, studies on these units have great significances.
直接空冷凝汽器由一个个直接空冷单元组成,对直接空冷凝汽器单元的研究具有重要的意义。
The mathematical model for two-phase flow and heat transfer of wet steam in exhaust pipe for a 600 MW power generating unit with direct air cooling is established.
建立了600MW发电机组直接空冷排汽管道内湿蒸汽两相流动和传热的数学模型。
The main factor affecting the heat-exchanging performance of direct air cooling condenser is backflow or recirculation of the hot air resulted from the ambient strong wind.
影响空冷凝汽器换热性能的主要因素是环境大风所造成的热风回流或热风再循环。
Antifreezing is always a notable problem in the start-up in winter, shutdown process and low load operation period of air cooling condenser of large size direct air cooling unit.
大型直接空冷机组空冷凝汽器在冬季启动、停机过程以及低负荷运行阶段的防冻问题尤为突出。
The transformed air-cooling condenser of the heating unit of the NO. one Thermal Power Plant of Datong is the first direct air cooling in China, and is very important in water saving.
大同第一热电厂供热机组替代改造工程空冷凝汽器是国内首台大型直接空冷,对于节省水力资源具有十分重要的意义。
Large area freezing, damage etc. failures occen occur on the air cooling condensers during start-up and shutdown of large size direct air cooling coal-fired generating units in winter.
大型直接空冷燃煤发电机组在冬季启停过程中,空冷凝汽器常常会发生大面积冻结、损坏等事故。
Through tests and exploration, the cause of vacuum fluctuation in summer was found, in the direct air cooling unit, the output of vacuum pump had obvious influence on the variation of vacuum.
经过试验和探索,找到了夏季真空波动的原因,在直接空冷机组中,真空泵出力对真空的变化有明显的影响。
The paper analyzed reason of excessive dissolved oxygen in condensate of direct air-cooling combined heat power generation units in Yungang Thermal Power Co.
分析了云冈热电直接空冷供热机组凝结水溶氧超标的原因,提出了凝结水补水系统存在的问题及解决方案。
CFD software is used to perform 3-d numerical simulation of steam flow field inside direct air-cooling exhaust steam pipe of a 660 MW supercritical unit.
利用计算流体动力学软件(CFD),对某660MW超临界发电机组直接空冷排汽管道内的水蒸汽流场进行了三维数值模拟研究。
Direct air-cooling technology is the best choice of steam power station in the area rich in coal but short of water.
直接空冷技术是富煤缺水地区建设火力发电厂的最佳选择。
This paper introduces the allocating modes of main test points of the condenser behavior test in the direct air-cooling units, and discusses the guarantee conditions of the test.
针对直接空冷机组空冷凝汽器特性试验中的主要测点的布置方式以及试验的保证条件进行了一些探讨。
This paper introduces the allocating modes of main test points of the condenser behavior test in the direct air-cooling units, and discusses the guarantee conditions of the test.
针对直接空冷机组空冷凝汽器特性试验中的主要测点的布置方式以及试验的保证条件进行了一些探讨。