• If the column is defined as null capable, then you must update the null indicator map accordingly.

    如果列被定义为支持空值,那么您必须相应更新空指示符映射。

    youdao

  • RPG uses a 1 character field (like an indicator) to determine if a column contains nulls.

    RPG使用一个1字符字段(比如一个指示符)来确定列是否包含空值。

    youdao

  • If the latter is true, then the indicator variable for that column is set to -5 which will set the column to the default value for that column.

    如果是后一种情况,那么该列的指示符变量被设置为- 5,这将把该列的值设置为默认值。

    youdao

  • If the former is true, then the indicator variable for that column is set to -1 which results in the column being updated with the null value.

    如果是前一种情况,那么该列的指示符变量被设置为- 1,这导致该列被更新为空值。

    youdao

  • The indicator variable for the column is set to zero for each value that is different.

    对于每个不同的值,该列的指示符变量被设置为0。

    youdao

  • The Ind_Ary column contains the SQL extended indicator settings.

    Ind_Ary列包含SQL扩展指示符设置。

    youdao

  • If the old and new values are the same, then the indicator variable remains as -7 and the column is ignored.

    如果新旧值相同,那么指示符变量仍然是- 7,该列被忽略。

    youdao

  • Prior to the DB2 for I 6.1 release, SQL Update and Insert statements could use an indicator variable with a value of -1 to set a null capable column to the null value.

    在DB 2fori 6.1发布之前,SQLUpdate和insert语句能够使用一个值为- 1的指示符变量,将支持空值的列设置为空值。

    youdao

  • Apply to relay Box for alarm indicator connecting between several alarm indicator column and alarm indicator board.

    用于继电器箱与多个警报指示柱,警报指示器板间的连接。

    youdao

  • The analysis of a double column pier has proved that this damage assessment model can give a simple, reasonable and consistent damage indicator for structures.

    通过一座双柱式桥墩的计算分析表明,采用这种方法可以简单、合理、可靠地得出结构的损伤值。

    youdao

  • Apply to relay Box for alarm indicator connecting between several alarm indicator column and alarm indicator boa...

    用于继电器箱与多个警报指示柱,警报指示器板间的连接。

    youdao

  • In embedded SQL, an indicator variable is set to -2 for the column or columns that cause the error.

    在嵌入式SQL中,对于导致错误的列,指示符变量设置为- 2。

    youdao

  • A final column in Table 5-1 indicates the amount over or under the budget for each category. This column is an indicator of the extent of variance from the project budget;

    表5-1的最后一栏显示了每一项次预算超支或勤俭的数值,这一栏也是预算偏差的唆使器。

    youdao

  • A final column in Table 5-1 indicates the amount over or under the budget for each category. This column is an indicator of the extent of variance from the project budget;

    表5-1的最后一栏显示了每一项次预算超支或勤俭的数值,这一栏也是预算偏差的唆使器。

    youdao

$firstVoiceSent
- 来自原声例句
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定