The laser collimator not only has the advantages of existing ones, but also can be used to measure wavefront error with high accuracy interferometer.
此激光平行光管具有以前平行光管的优点,且可以与数字相移干涉仪对接,直接进行波前误差的高精度测量。
We also design a novel UV collimator which makes infinite UV testing targets. It can reduce the difficulty of optical design and the machining cost, and utilize UV energy at maximum extent.
分辨率测试装置中采用非球面设计反射式平行光管,形成无穷远紫外分辨率目标,不仅减少了设计和加工成本,而且使紫外能量得到了最大程度的利用。
The collimator lighting remains also switched on.
准直仪照明仍然保持开启。
One problem is simply the design of the collimator and condenser.
第一个问题仅是准直镜和聚光镜的设计。
Purpose to study the clinical applying value of multi-leaf collimator.
目的:研究多叶准直器在临床的应用价值。
In this paper, a measuring method of convex lens foci in collimator is given.
介绍一种测量平行光管内凸透镜焦距的测量方法。
In this paper is advanced a new type of collimator-dual sieve-mesh collimator.
提出了一种新型的准直器——双筛孔式准直器。
The collimator is an important equipment for optical experiment and standardization.
平行光管是光学实验及计量检测的重要设备。
Photoelectric collimator is a kind of simple fire-control system equipped on a weapon system.
光电瞄具是配备于某武器系统上的一种简易火控系统。
The system consists of PSD, laser vertical collimator, data sampling box and application software.
该系统包括PSD,激光垂直准直器,数据采集箱和应用软件四个部分。
The portable laser collimator and the straightness measuring and evaluating software are developed.
开发了便携式激光准直仪及直线度误差测量、评定软件。
The simplest approach to radiosurgery is to use a single, fixed collimator to shape the treatment field.
对于放射外科来说,塑造治疗射野最简单的方法是采用单一、固定的准直器。
This provides technological guarantee for the auto-collimator whole-range measurement repetition precision.
为自准直仪的重复测量精度提供了技术保证。
Quantum integration noise reducer and collimator can be used to improve the inspection sensitivity of the system.
可采用加准直器和光量子积分降噪的方法提高检测灵敏度。
The alternative approach is to switch one collimator for another midway through treatment, altering the field size.
另一种可供选用的方法是在治疗过程中通过更换不同类型的准直器来改变射野大小。
This paper deals with the leaf shape design of multi-leaf collimator used in 3-dimensional conformal radiation therapy.
讨论了三维适形放射治疗中的多叶组合光栅的叶片设计。
Focusing collimators were used instead of single collimator to increase the scattering photon flux received by detector.
提出利用聚焦准直器代替单个准直器以达到增大探测器接收到的散射光子通量的目的。
The dynamic object should arrive at the view field of the collimator in the camera exposure time to simulate infinity object.
在相机拍照曝光时间内,尺形分辨率板运动至平行光管的视场内,以模拟无限远动态目标。
The major advantages of the present invention include shortened optical assembly length and easy manufacture of the straight collimator.
本发明的最大优点是缩短了光学组件的长度,有利于降低直光管的制造难度。
With this model, all kinds of factors on the coupling efficiency and collimation degree of the muti-mode fiber collimator were analyzed.
利用所建立的模型,分析了各种因素对光纤准直器耦合效率和准直度的影响。
This sensor featuring plane-convex lens collimator for expanding beam and coupling, and a low frequency for light pulse modulation is introduced.
利用平-凸透镜准直器作扩束耦合光学系统,采用低频斩光器实现光调制。
The theory and testing methods for single-mode agonic fiber optic collimator are introduced and some fabrication processes are discussed and compared.
介绍了单模无偏准直器的原理与测试方法,并对一些制作工艺进行了讨论和比较。
The result proves that the efficiency of multi-pin-hole collimator is indeed higher than that of single-pinhole collimator for our hypothetical model.
结果表明,所假设模型基础上,多针孔成像确实在一定程度上要比单针孔成像探测效率高。
The influence of imaging magnification and the ratio of object dimension to object-to-collimator distance on imaging efficiency was investigated as well.
最后还分析了放大倍数以及物体尺寸相对于物距的大小对探测效率的影响。
It needs a down-collimator to convert big beams of a large laser facility into smaller beams in diameter to fit measurement instruments in diagnostic system.
大型激光装置中的参数诊断系统需要使用缩束系统,将被测脉冲转换为小口径光束,以匹配相应的参数测量仪器。
The whole optical system using the materials of Ge and si consisted of 11 elements, including 3 lenses for collimator and 7 lenses for the projection system.
整个光学系统采用锗和硅两种材料,包含11片透镜,其中:准直物镜3片,投影镜头7片,场镜1片。
With a collimator and a 23 polyhedron as measuring datum, a set of optical angular encoder measuring data, which containing the eccentricity error, was obtained.
以平行光管和23面棱体为基准,得到存在偏心误差的一组光栅角编码器测量数据。
The commutation rule and the optimal collimation area are analyzed when Gauss light beam passes thin lens, and the design principles of the collimator are given.
阐述高精度激光准直系统的总体构成及特点,着重分析高斯激光束经过薄透镜的变换规律、最佳准直区域以及激光准直光学系统的设计思路。
Because of the projection image overlap due to coded-pinhole collimator, the completeness of projection data and volume image reconstruction algorithm are discussed.
还针对编码针孔准直器的投影混叠问题,讨论了投影数据完备性和体积图像的重建方法。
Because of the projection image overlap due to coded-pinhole collimator, the completeness of projection data and volume image reconstruction algorithm are discussed.
还针对编码针孔准直器的投影混叠问题,讨论了投影数据完备性和体积图像的重建方法。
应用推荐