Calibration takes place in this step.
校准也是在这一步中进行。
Through the dynamic calibration experiments, the step input and output signals with different amplitudes are obtained.
通过动态标定实验,得到不同幅值的阶跃输入、输出数据。
The calibration of a camera system is a key step to the precise conversion between an image of machine vision and the real dimension.
成像系统标定是机器视觉测量系统所成图像和实际被测尺寸之间实现高精度转换的关键过程。
As an important step during the application of microscopic simulation, calibration of the simulation model can effectively ensure the accuracy of simulation and the reliability of the conclusions.
仿真模型的校正作为微观仿真技术应用的重要步骤,能有效保障仿真精度和应用结论的可靠性。
The polarimetric calibration is an important step to acquire the accurate polarization scattering matrix and is extensively difficult for the large aperture polarimetric radar.
极化校准是极化散射矩阵正确获取的重要步骤之一,大口径雷达的极化校准一直是一个难点。
In the first chapter, we introduce linear camera model and some general knowledge and several traditional methods of camera calibration, such as Direct linear Transformation and two-step method etc.
第一章介绍了线性摄像机模型以及摄像机定标的一般性知识和几种常见的传统定标方法,比如直接线性变换方法和两步法等。
If the results are out of the calibration range, return to step 5 of the phthalate extraction method (perform another dilution to get results in calibration range).
如果结果超出校准范围,重复邻苯二甲酸酯方法步骤5(另外稀释使结果落入校准范围内)。
The precision of step calibration is low because more middle parameters need to be measured during calibration.
分步定标法需要测量的中间参数较多,故误差来源多,定标精度低。
The step calibration signal has been widely used in seismograph calibration and check.
阶跃信号在地震仪的脉冲标定和检查中获得了广泛应用。
The step response method should be applied in the dynamic characteristic calibration of the 6-aixs wrist force sensor for robot and some comparisons are made with other calibration methods.
通过对机器人六维腕力传感器系统的各种标定方法的分析讨论,说明了应采用阶跃响应的方法来对它的动态性能进行标定。
For the first two kinds the equations of motion and transfer functions are known. The coefficients of the transfer functions are determined by means of classical step-by-step calibration.
前两种地震仪,它们的运动方程和传递函数已知,传递函数系数可以通过经典的分段标定方法求得。
The results of the paper is significant in error analyzing of dynamic calibration of systems using step-function signals as the input.
本文对采用阶跃信号动态校准系统的误差分析具有重要的意义。
The third step, a new method of high-precision calibration with grating grooves is presented for the optical imaging system.
再者,提出了一种新的使用光栅刻线进行成像系统精度标定的方法。
A method has been developed to obtain analytically the seismometer parameters in time domain based on the step calibration function.
提出基于阶跃响应在时域解析测定地震计参数的方法,并对合理确定响应的时间零点提供了一种方法。
To solve the instability of the equivalent factor, a novel two-step calibration method is proposed.
为了解决等效因子的不稳定性,提出了一种两步标定法。
The main sources of uncertainty come from non-linear calibration models and pre-processing step of samples.
测量误差的主要来源是样品校正曲线拟合误差、样品测定重复性标准偏差。
Based on the four-step demand model with a feedback loop, a feedback mechanism with on-line travel time parameter calibration is proposed.
以引入反馈机制的四阶段需求模型为基础,提出带有在线出行时耗参数标定的反馈机制。
Based on the four-step demand model with a feedback loop, a feedback mechanism with on-line travel time parameter calibration is proposed.
以引入反馈机制的四阶段需求模型为基础,提出带有在线出行时耗参数标定的反馈机制。
应用推荐