Pilot burner system. LP gas or city gas, Pilot burner is ignited manually before each test.
点火用气可选用液化石油气或者煤气,每次试验前需要手工点火。
An efficient burner system is essential for obtaining optimal performance from you AA instrument - and proper maintenance is required to obtain precise and accurate determinations.
高效的燃烧器系统对于获取原子吸收光谱仪的最佳性能至关重要,必须进行适当的维护,才能获得精准的测定结果。
The way this burner system melts metal is simply by pushing the flame exit port up against the hole in the furnace which ordinarily would hold the propane burner (or air blast on a charcoal furnace).
这种燃烧器的方式系统的金属熔体的火焰推出境口岸打击在炉内的通常会举行一个木炭炉的丙烷燃烧器。
This is a system that relies on magnets in both the burner and special POTS and produces heat only when the two are in contact.
这是一个系统,都依赖于对磁体的燃烧器和特殊盆和产生热量只有在两个接触。
Fire the burner to bring system up to design temperature.
开启锅炉或热水器,使系统上升到设计温度。
In the drying system the combustion temperature of burner is the very important parameter, contrapose the burner, makes theoretically research of temperature controlling.
烘干系统中燃烧器的燃烧温度是至关重要的参数,本论文针对燃烧室温度控制作理论上的研究。
The concept of furnace combustion management through introduction on line monitoring system with pulverized coal burner was put forward.
通过介绍煤粉燃烧器在线监测系统,提出了炉膛燃烧管理这个概念。
In comparison with the conventional tangentially fired system, the horizontal bias burner and the twin circles of the primary air are two main improvements.
与传统的切圆燃烧系统相比,水平浓淡燃烧器和同层一次风双向切圆布置是该系统的主要改进之处。
The advantages and disadvantages of switch type regenerative combustion system are analyzed and one self-regenerative high temperature air burner which could continuous combust is developed.
分析了切换式蓄热燃烧系统的优点与不足,开发了可连续燃烧的自蓄热高温空气燃烧器。
The paper introduces the structure of TRW liquid slagging burner and main features of burning technology, emphasizing on the control and management system of TRW burner.
介绍TRW液态排渣煤燃烧器的结构及燃烧技术的主要特点,着重介绍TRW燃烧器的控制和管理系统。
In tangential combustion system, the reheat steam temperature can be adjusted by changing burner nozzle Angle to just the flame position.
在切向燃烧系统中,通过改变燃烧器喷口的角度可以调节炉内火焰中心位置,可达到调节再热汽温的目的。
A burner management system and a combustion control system are used to maintain low Nitrogen oxide and Carbon Dioxide emissions which are major environmental concerns.
燃烧器管理系统和燃烧器控制系统用于保持氧化氮和二氧化碳的低排放量,减少对空气的污染。
Mainly by modifying the control logic of the burner management system (BMS), the defects of the system are redeemed to enable its reliable operation.
通过修改锅炉燃烧器管理系统(BMS)的控制逻辑和增加保护的投入,弥补了系统的缺陷,保证灭火保护系统安全可靠地投入使用。
If you already have a CD burner and software installed in your machine, you probably have the tools to create a complete system backup - for only the cost of a few CD-R's!
如果你已经安装在你的光盘机燃烧器及软件、你也许有一个完整的系统备份工具制造工成本仅几cd-R光盘的!
An experimental study was conducted of the cold-state flow field of a dual swirl gas burner model through the use of an IFA300 type two-dimensional constant-temperature hot-wire anemometer system.
利用IFA300型二维恒温热线风速仪系统对双旋流气体燃烧器模型的冷态流场进行了实验研究,测量了流场内不同位置瞬时速度分布及湍流强度特性。
Boiler's burner management system (BMS) is an important part of distributed control system (DCS) in large-scale unit.
锅炉燃烧器管理系统(BMS)是大型机组分散控制系统(DCS)的重要组成部分。
It is widely used on flame control in the combustion control system and air-burner heat system of various industry kiln.
广泛应用于各行业工业炉窑燃烧控制系统及大气烧嘴加热系统的火焰控制中。
Good knowledge and experience of machine control, transmission, burner technology, well know plant utility system.
熟悉设备控制,良好的传动,火炉知识和经验,熟悉工厂公用设施。
Homemade equipments were adopted in this line largely, as well as some proprietary and patent technology of NCDRI in firing system, coal dust burner and coal mill system.
该线大量采用国产化设备,烧成系统、窑头喷煤管、煤磨系统等应用南京院专有专利技术。
This paper introduces the application of the flame temperature adjustable high velocity burner and the pulse type system of temperature adjustable in aluminum ingot heating furnace.
介绍了高速调温烧嘴及脉冲式控温系统在铝锭加热炉上的应用情况,采用了炉顶垂直安装高速烧嘴的形式,取得了满意的加热效。
The paper presents the dust collect system of Germanium coal reverberatory burner in modified plant and discusses related problems.
文章介绍了某厂改造后的锗煤反射炉收尘系统,并对该收尘系统中存在的问题进行了分析和探讨。
A burner management system for power plant boiler by using HS2000 and the application of it in Guiyang thermal power plant are presented in this paper.
介绍由hs2000系统完成的动力锅炉燃烧器管理系统,具体描述了它在贵阳电厂的应用。
Can solve the part of the heating furnace combustion system requirements, the fast speed of small, burner graphically-intensive etc.
可解决当前部分工业炉燃烧系统的升温速度要求快、炉型小、烧嘴分布过于密集等情况。
At all four Tanda units, the Ovation system will monitor and control the burner management system (BMS) and furnace safeguard supervisory system (FSSS).
在Tanda的全部四个机组内,Ovation系统将监测和控制燃烧器管理系统(BMS)以及煤炉安全监控系统(FSSS)。
Advanced equipment and process of secondary steelmaking are adopted in the combustion system of Baosteel No. 2 RH, which consists of stand by burner and multifunctional top lance systems.
宝钢二号RH装置的加热系统引进了世界上先进的炉外精炼工艺与设备,由预热和多功能顶枪系统两大部分组成。
Advanced equipment and process of secondary steelmaking are adopted in the combustion system of Baosteel No. 2 RH, which consists of stand by burner and multifunctional top lance systems.
宝钢二号RH装置的加热系统引进了世界上先进的炉外精炼工艺与设备,由预热和多功能顶枪系统两大部分组成。