• That is, when the line failure, the relay circuit breaker tripping, the device auto-reclosing after a short time interval, so that a re-breaker.

    线路出现故障继电保护使断路器跳闸后,自动重合闸装置时间间隔后使断路器重新合上。

    youdao

  • The recloser controller has logical structure, applicable function, high reliability, and can protect and control effectively aerial line outdoors of 10 KV electric power with outdoors vacuum breaker.

    控制器结构合理功能适用、可靠性户外真空断路器配套使用,电力10KV户外架空线路进行有效保护控制

    youdao

  • The operating logics and processes of the automatic transfer of the incoming line breaker and the bus-tie switch are presented.

    给出了线断路器自投母联开关备自投工作逻辑和投切过程

    youdao

  • With an example of two lines short and grounding fault, and one side of breaker of grounding fault line being cut off, the paper illustrates the principle of this calculation method.

    文中线接地横向故障接地故障线一侧断路器断开后的复杂故障为例阐明了该算法的原理

    youdao

  • For example, screaming blood fury is great ice-breaker at parties. And fast movement good for getting to front of buffet line.

    比如血腥复仇咆哮声聚会上很适合用来打破冷场。迅捷移动让你可以立刻前往餐桌前线

    youdao

  • The large power station is strict to the electrical connection scheme, the application of angle scheme usually influenced by overhaul of line breaker which cause unloosed topology.

    大型电站接线可靠性要求更为严格,接线应用往往受到断路器检修,即开环运行的影响。

    youdao

  • The various selection methods of low voltage breaker when it was applied in distribution line, motor and lighting are introduced as well as the corresponding installation requirements.

    介绍低压断路器分别应用配电线路电动机照明选择方法,并安装时应满足的具体要求作了阐述,提出了断路器在使用和维护过程中应注意的事。

    youdao

  • Protection against motor over - load usually adopt thermal relay, but protection against line over - load usually adopt long delay over- current release of circuit- breaker.

    电动机过载保护通常采用继电器配电线路过载保护采用断路器延时电流脱扣器来完成。

    youdao

  • In the paper a new structure of the developed vacuum circuit breaker with the on-line dynamic contact force compensation by means of the contact current is presented.

    论文提出了一种新型真空断路器结构结构可以利用电流在线动态补偿触点压力

    youdao

  • This paper introduces the configuration of an on-line monitoring device based on type 80C196KC20 MCU aiming at monitoring the SF6 circuit breaker.

    阐述种以80C196KC20单片机为核心,以SF_6断路器监测对象的在线监测仪的系统构成。

    youdao

  • This paper introduces a method that the mechanical condition of circuit breaker can be monitored and diagnosed on-line.

    介绍一种断路器机械状态在线监测诊断方法

    youdao

  • So it is necessary to develop the on-line monitoring and fault diagnosis for the real-time state of he HV circuit breaker.

    高压断路器大部分故障源于机械方面,因此研究机械故障具有重要意义。

    youdao

  • It is an effective approach to ensure the non-exceeding of the breaking capacity of line breaker by adopting fault current limiter to restrain short-circuit current when the grid is in fault.

    采用故障电流限制器抑制电网故障短路电流保证断路器遮断容量不致超限有效方法

    youdao

  • Analysis of factors impacting on operation of optic protections, putting forward channel switch scheme of fiber protection when bypass breaker as line breaker.

    分析影响光纤电流纵差保护正常原因,提出通道切换方案以及日常运行管理的几点建议。

    youdao

  • With the structure as exterior impact the user's vision, also reflected the reliability of products, in line with the circuit breaker this kind of product characteristics.

    结构作为外观冲击用户视觉体现产品可靠性符合断路器产品的特点。

    youdao

  • The paper analyse the requirements and implementation ways for protection of LV distribution line. Type selection and parameter setting of fuse and circuit-breaker are introduced.

    系统地分析低压配电线路保护要求实施方法,叙述了熔断器断路器选型,及其参数定;

    youdao

  • This paper presents a new on-line monitoring system for vacuum circuit breaker.

    介绍一种研制的真空断路器新型智能在线监测系统

    youdao

  • Through analyzing the reclosing of circuit breaker in middle of line-transformer strings, the existing problems were figured out and the modification measures were put forward.

    通过对线-变开关重合闸问题分析找出存在问题,提出改进意见。

    youdao

  • A direct operation way of replacement line breaker on load by using line jumper was introduced, which is in accordance with the safety codes and the hot line maintenance rules.

    阐述使用线路接器带负荷更换线路断路器直接作业方法方法符合安全规程带电作业规程的要求,具有实用性。

    youdao

  • HV and EHV transmission lines are equipped with split-phase breaker. If a longer reclosing time is setting in a heavy load line, the system may swing after the trip without fault of remote breaker.

    高压超高压输电线路开关分相开关,对侧开关单相偷跳线路负荷比较、同时重合闸动作时间比较长的情况下可能引发系统振荡

    youdao

  • This paper presents a new design scheme of temperature on-line monitoring system of high voltage circuit breaker based on wireless communication.

    提出一种新型基于无线通信高压断路器温度在线监测系统设计。利用先进的温度传感器ds18 B 20采集现场的实时温度。

    youdao

  • This paper presents a new design scheme of temperature on-line monitoring system of high voltage circuit breaker based on wireless communication.

    提出一种新型基于无线通信高压断路器温度在线监测系统设计。利用先进的温度传感器ds18 B 20采集现场的实时温度。

    youdao