摘要:非能动系统是保障核电站安全的一个重要途径。
Abstract: Passive system is an important way to protect the safety of nuclear power plants.
基于非能动系统的定义和主要特性,对其可靠性进行分析。
Based on the definition and main characteristics of passive systems, the reliability of it is analyzed and a specific analysis is given.
该系统是以非能动系统为基础设计的,并实现了传动、导向一体化。
Design of this system is based on passive system, integrating drive and guide of control rod.
结合研究情况,初步给出了中国实验快堆非能动系统可靠性研究方法。
The passive system reliability is demanded to go deep into research. Combining with the current research, reliability of residual heat removal system of passive systems in CEFR is preliminary formed.
在研究核电站安全时,热工水力非能动系统的可靠性研究基于所建立的热工水力学数值模型。
In safety research of nuclear power plant, the reliability research of thermal hydraulic passive system bases on the numerical models.
介绍了密闭输送管道的梭式非能动控制调节系统。
The paper introduces shuttle passive control systems in the field of airtight pipeline transportation.
非能动余热排出系统是模块式高温气冷堆(MHTR)实现固有安全性的重要保证。
Passive residual heat removal system is the key assurance for the inherent safety of modular high-temperature gas-cooled reactor (MHTR).
利用RETRAN 02程序,以全厂断电事故为设计基准事故,对TANES非能动余热排出系统的余热排出能力进行了计算。
The RETRAN02 code was used to calculate the ability of the passive PRHR system of TANES at the design-based accident of losing conventional and dependable electrical power under full power.
实验研究表明:三大非能动安全系统的设计是合理、可行的,基本能满足其赋与的功能要求。
These experiments proved the design of these passive systems are feasible and reliable and can meet basically the required safety functions.
遮流板的使用可以有效提高反应堆非能动注水系统的安全性。
The use of sparger can improve the safety of the negative water - supply system efficiently.
非能动安全壳冷却系统(PCCS)水分配装置是PCCS的重要组成部分,也是系统功能能否实现的关键。
The water distribution device is an important part of the Passive Containment Cooling System (PCCS), which is a key to carry out the function of the PCCS.
提出了一种用于钍基先进核能系统压力管与排管之间的非能动热开关设计方案。
The paper presents a design of passive heat-switch between pressure tube and calandria tube of Thorium-based Advanced Nuclear Energy System.
非能动的系统由大容积的水箱(安注箱)组成,箱内装有硼水,上部由带压的氮气覆盖。
The passive systems consist of large volume tanks (accumulators) which are filled with borated water and pressurized with nitrogen gas.
摘要:AP1000有其固有的安全性能,由于采用非能动安全系统,大大降低了发生人因错误的可能性。
Abstract: AP1000 has its inherent safety performance, and the application of the non kinetic energy security system greatly reduces the occurrence of human error probability.
摘要:AP1000有其固有的安全性能,由于采用非能动安全系统,大大降低了发生人因错误的可能性。
Abstract: AP1000 has its inherent safety performance, and the application of the non kinetic energy security system greatly reduces the occurrence of human error probability.