零序电流保护是一种重要的接地保护方法。
The zero-sequence current protection is an important means of power system ground protection.
介绍了湖北电网零序电流保护整定计算程序的主要功能和特点。
The major function and features of the calculating program for Settings of zero sequence current protection of Hubei power system were described.
主要介绍了零序电流保护整定计算程序的主要功能和特点,简要介绍了双回线零序电流的不平衡解决方法。
Main functions and characteristic for zero sequence current protection setting program are presented in this paper. Ways of no_balance zero sequence current for double lines are introduced.
文中算法已在大电网零序电流保护整定计算软件中实际应用,结果表明,算法在计算速度和精度方面均满足要求。
The application results show that the calculation precision can meet the needs of relay setting and coordination, and its calculation efficiency can make relay setting and coordination faster.
介绍了接地故障保护的几种不同方式,从接地故障保护、零序电流保护、剩余电流保护等方面进行了论述,指出只有与等电位联结相结合,才能完善保护作。
Several different protection ways for earth fault are introduced and discussed from earth-fault protection, zero-sequence protection, residual current protection and other aspects.
另外还需要进行变压器零序方向过电流保护动作方向正确性的检查。
The validity check of zero-sequence operating direction for transformer directional over-current protection is also essential.
本文针对高压输电线距离保护及故障测距中常用的解微分方程算法,提出了一种零序电流相位修正的方法。
The paper proposes a method which corrects the Angle of zero-sequence current in the algorithm of differential equation used for distance protection and fault location of HV transmission lines.
该文提出一种新的基于负序电流补偿的自适应零序过电压保护原理。
A novel principle of negative-sequence current compensation based adaptive zero-sequence over-voltage protection is therefore proposed.
针对单纯采用相电流判据的不足之处,本文提出增加零序电流、负序电流及电流变化量判据,以有效地避免保护误动或者拒动。
Zero-sequence current criterion, negative sequence current criterion and phase current variation can be used to improve the performance of breaker failure protection for ACF sub-bank.
对近期提出的克服电网分布电容影响小电流接地选线的零序直流选择性保护原理作了理论分析。
This paper analyses the existing zero sequence directive current selective leakage protection principle which is to surmount the effect of distributed capacitance on it.
在基于零序电流方向原理的矿井低压电网选择性漏电保护中,比相误差是导致保护误动的主要因素。
The phase comparison error is the primary factor leading to mistaken action in the selective leakage protective system of underground LV networks based on zero sequence current direction.
配合SD - LJD (LXK)系类零序电流互感器和动作继电器即组成完整的零序(接地)保护系统。
Used together with SD-LJD (LXK) series ZCT and executing relay to form a complete zero sequence (ground) protection system.
论文根据上述分析设计了基于故障分量采样值差动保护、故障分量相量差动保护、常规电流差动保护和零序电流差动保护自适应的保护方案。
The setting schemes of the resistance coefficient and the least trip differential current for the current differential protection based on sampled values using fault component are discussed.
本装置配有过流保护、负序电流保护、零序电路保护、起动时间过长保护、低电压保护。
Over current protection, negative current protection, zero sequence current protection, over time of start protection and low voltage protection is configured in the device.
基于对称分量法理论,提出了基于检测正序、负序、零序电流分量的电动机保护方法。
Based on the symmetry component theory, a method of the motor protection is presented by measuring positive, negative and zero sequence current component.
将零序电流加速保护与距离保护相配合得到自动重合闸加速保护综合方案,改善了重合闸后加速保护的性能。
According to the schemes, a general schemes for auto recloser accelerating protection is presented which improves performance of accelerating protection.
该保护装置自具电源,基于热量累积原理实现快速高精度相电流反时限保护方法,实现对相电流和零序电流三段式保护。
The power of the protector is supplied by itself from the ct. Based on thermal cumulate principles, a rapid and high precision inverse-time phase-sequence over-current protection is implemented.
该保护装置自具电源,基于热量累积原理实现快速高精度相电流反时限保护方法,实现对相电流和零序电流三段式保护。
The power of the protector is supplied by itself from the ct. Based on thermal cumulate principles, a rapid and high precision inverse-time phase-sequence over-current protection is implemented.
应用推荐