运用电报方程推导出三线-地耦合传输线零序分量和正序分量传输线方程。
The zero sequence component and the positive sequence component equations of transmission lines are derived on the basis of telegraph equations.
小电流接地系统发生单相接地故障时,对零序分量而言,非故障线路相当于空载。
The healthy line is unloaded for zero-sequence component when a single-phase fault occurs in a non-solid earthed network.
提出一种用零序分量做动作量,负序分量做制动量的综合序分量接地距离继电器。
An earth fault distance relay based on the combined sequence components is presented.
由于该方法中没有用到线路两真个零序分量,消除掉耦合线路之间零序互感对测距的影响。
Because there is no need for acquiring the zero-sequence component, this principle can eliminate the effect of zero-sequence mutual inductance between coupling lines.
该文基于三磁柱变压器及三磁柱电感的动态方程建立了带三磁柱电感及三磁柱变压器的三相逆变器瞬时零序分量模型。
In this paper, the instantaneous model of zero-sequence circulating current between parallel three-phase inverters with three-pole reactors and three-pole transformers is established.
分析表明,即使系统不存在零序回路,DVR都会在补偿控制中向系统注入微小的零序分量,该零序分量会对无零序回路系统侧电压造成不良影响。
It shows that DVR will inject small zero sequence component into the power system during compensation control even if there is no zero sequence circuit. This will influence the voltage on system side.
为此,提出了新的控制策略,该控制策略通过检测并消除指令中的零序分量,以破坏无零序电流回路系统的零序电压正反馈条件,消除DVR注入零序电压的不良影响。
So a new control strategy is proposed to detect and suppress the influence of zero sequence component injected by DVR. Simulation results show that the proposed strategy is co…
建立了基于模分量大小和三相及零序电流大小的模糊数学模型,能快速准确的识别振荡中发生的不对称故障。
Establish the fuzzy set based on modulus component, three phases and residual current, which can distinguishing unbalance faults from power swing rapidly and reliably.
基于对称分量法理论,提出了基于检测正序、负序、零序电流分量的电动机保护方法。
Based on the symmetry component theory, a method of the motor protection is presented by measuring positive, negative and zero sequence current component.
根据对称分量法,推导了两种软件计算零序电流的方法。
Two methods to calculate the zero sequence current are deduced based on the symmetrical component method.
在典型的六相输电系统中,半正序、半零序和半负序故障分量不受系统阻抗变化的影响。
In typical six-phase transmission system, half positive sequence, half zero sequence and half negative sequence fault components are independent of the variance of system impedance.
结合自动补偿电网的特征,对利用零序电流的附加有功分量进行单相接地故障选线进行了研究与分析。
The paper made research and analysis on the topic of faulted line selecting in an auto compensated distribution network in use of the active part of residual currents.
论文根据上述分析设计了基于故障分量采样值差动保护、故障分量相量差动保护、常规电流差动保护和零序电流差动保护自适应的保护方案。
The setting schemes of the resistance coefficient and the least trip differential current for the current differential protection based on sampled values using fault component are discussed.
文中用六序分量法分析了同杆双回线上零序功率方向继电器的性能。
Based on the method of six sequence fault component, this paper analyses the performance of zero sequence directional relay on double circuit line on the same pole (DLSP).
实验结果表明,该装置可对三相四线制系统中的谐波、负序、零序等电流分量进行补偿。
Experimental results prove the proposed control method can compensate the harmonic, negative sequence and zero sequence current components in the three phase four wire.
文中讨论了零序电流暂态分量的大小和提取方法,对数字仿真和混合仿真试验数据进行分析,结果表明零序电流暂态分量用于单相接地故障识别是可行性的。
We choose the transient zero current prior to others, for it is bigger than others mostly. This paper discusses the size of transient zero current and the method of analyzing it.
文中讨论了零序电流暂态分量的大小和提取方法,对数字仿真和混合仿真试验数据进行分析,结果表明零序电流暂态分量用于单相接地故障识别是可行性的。
We choose the transient zero current prior to others, for it is bigger than others mostly. This paper discusses the size of transient zero current and the method of analyzing it.
应用推荐