通过这些手段可以减小部分误差,使得所建的模型更符合实际情况。
By these means can reduce the part of the error, making the models built more in line with the actual situation.
在任一特定的情形下,实验的实际情况是,其结果的变化要么符合正态误差法则,要么不符合这个法则。
In any particular case, it is a matter of experimental fact whether the variations are in accordance with the normal law or not.
应用数学演绎推理法证明了这种基准使位置误差偏移值最小,又符合实际装配工作条件,比较理想。
Mathematical derivation proves that the reference makes the offset of position error more small, and accords with the running condition of practical fixation, which is more ideal.
此外,为符合会聚误差测量中栅极驱动脉冲特定带宽的要求,脉冲的高技术指标仍然是不可缺少的因数。
In addition, the demanding technical specification is still indispensable factor, which accords with the special bandwidth demand of the grid drive pulse in measuring the convergence error.
最小区域法是符合最小条件的一种直线度误差评定方法,但较难实现。
The minimum zone method meets the minimum condition for evaluating the straightness, however it is difficult to accomplish computerization.
实验结果完全在误差范围允许之内,并且符合表面等离子振荡的理论现象及其调制模拟演算结果。
All of the results are within the accepted error range and accord with the theory and numerical simulation.
用最小区域法求直线度误差,是在最小二乘法的基础上探讨的一种符合最小条件的新方法。
Computing straightness error on the basis of least square method by way of smallest field method is new method in exploring the minimum condition.
结果表明,该模型收敛速度快,预测误差小,预测结果与实测结果较为符合。
The case study indicates the model has a quickly convergent velocity and less error, and prediction result is comparatively consistent with the experimental result.
预测结果表明,模型的近期预测误差控制在5%以内,完全符合财务评价要求。
The result indicated that the model's short-term prediction error is controlled with 5%, which conforms with the financial appraisal requirements.
经计算主测定路线上的通风阻力测定相对误差为1.94%,其精度符合要求。
The relative error of the ventilation resistance measured on the main measuring route was 1.94% and the accuracy could meet the requirement.
由于在估计方法中无需假定误差方差,因此,所构造的估计方法更符合实际应用情况。
Since there is no need to suppose the variance of error, the estimation method which we established is more efficient in application.
研究了几种直线度误差评定方法,其中最小区域法符合最小条件,应作为直线度误差评定结果的仲裁依据。
A few of methods of evaluating straightness error are researched. Minimum zone method tally with minimum condition, so it is ruling basis of evaluating straightness error.
实验结果与理论(蒙特卡罗方法)计算值在实验误差范围内相符合。
The experimental results accord with the values of theoretical calculation (Monte Carlo Method) in the experimental errors.
对在不同射角下符合时,由射表误差源造成的射程误差和偏流误差进行了计算与分析,论述了符合射角选择的合理区域。
The range error and drift error are calculated and analysed when the fitting is performed on different firing angle, so that a reasonable fitting region is chosen to decide the firing angle.
样本输出结果较理想值误差较小,分类器的识别结果完全符合实际情况。
The errors between output and ideal results of training samples were smaller.
与常用反时限保护特性相比较,此保护模型更符合负载的实际运行规律及保护要求,并对测量误差关系进行了分析。
Different from the common inverse time characteristic, this model conforms to the load actual operating law and the protection request, and takes the analysis of measurement error into consideration.
由上述实 心圆 轴的屈服强度公式计算出的屈服强度与两个屈服条件符合的很好,误差分别为1.7%和6.0%。
The yield strength derived according to the formula of solid cylinder specimen was accordance with Mises and Tresca yield criterions much better, and the relative error was separately 1.7% and 6.0%.
本文基于t分布理论,给出了用t检验准则来判断系统误差的方法,这是一种更符合实际测量情况的判断方法。
On the basis oft-distribution theory, this paper gives the method of judging system error with t-inspection criterion. This judging method is more suitable for the actual measurement situation.
在对重复压裂井进行产能评价时,常常认为初次压裂形成的裂缝完全失效,这种考虑与实际情况是不相符合的,导致对重复压裂井的产能预测有很大的误差。
When estimating productivity of refractured well, the primary fracture is considered to be disabled and it is not coincident with actual facts and a great error of prediction result exists.
最后,仿真了不同误差对测高精度的影响,实验结果符合理论分析的结果,为系统设计提供了一定依据。
Finally, the effect of different errors on height measurement accuracy is simulated, and some experimental results, which can supply to system design, are presented.
本文指出了叶片精加工的误差不符合正态分布规律,并推导了叶片精加工的误差概率分布函数。
The paper points out that the finish error of blades does not conform to normal distribution law, hence the error probability distribution function is derived for this specific process.
介绍一种按FGF判断法求符合最小条件直线度误差的快速算法,该算法很容易在计算机上实现,具有简单、明了的特点。
This paper introduces the fast calculating method in accordance with least condition linearity error with FGF judging method. The method is Yery easy to complete with computer, simple and clear.
并通过在自己研制的WATO机器人辅助手术系统上的模拟误差分析实验证明了所分析关键技术具有较高的精确度,符合手术的基本要求。
The experiments of error analysis in our WATO system demonstrate that the position and related calibration technologies have a high precision and can satisfy surgical requirement.
通过加入权重因子,利用反馈机制不断对产生的网络流量进行调整直至流量大小误差符合用户设定需求;
Via importing the power gene, using the reactive mechanism, continually adjusts the network traffic speed until the error matches the user's initialization.
论述了如何合理标注凸轮的公差要求和如何将凸轮测量数据处理成符合定义要求的不同误差形式的数值,并提出了与已往不同的凸轮评定方法。
The paper discusses the way to label cam tolerance in reason and turn cam data measured into different tolerance values that satisfies the definition. It also proposes a new assessment method for cam.
结论:采用神经网络法判定血透患者透析充分性与临床实际的符合率高,判断误差小,有临床实用意义。
Conclusion: Neural calculating method has higher accuracy in assessing the adequacy of hemodialysis patients and is clinically practical.
实验结果表明,仪器的重复性和稳定性精度误差基本在2%左右,检测结果符合正态分布。
In the test of instrument performance, the result shows that the tolerance at repeatability and stability is around 2% and the results are at normal distribution.
而齿列拥挤组的误差及上下颚咬合关系则需进一步的改进,以符合临床需求。
While, these differences for crowding dentition group are very significant and need further improvement.
检测用样品尺寸应符合美国ASTMF1470的规定,A级样品,接受值在任何情况下应做到零误差。
Sample size for testing shall be based upon ASTM F1470 Sample level A, acceptance number in all cases is zero defect.
检测用样品尺寸应符合美国ASTMF1470的规定,A级样品,接受值在任何情况下应做到零误差。
Sample size for testing shall be based upon ASTM F1470 Sample level A, acceptance number in all cases is zero defect.
应用推荐