完成电路连接之后,接通偏置电压,在没有离子束电流的情况下进行电流测量,以验证系统能够正常工作。
After the connections are made, verify the system is working properly by turning the bias voltage on and taking a current measurement with no ion beam current.
采用经钨带灯标准光源标定的多道石英光纤光学系统,测量了HL-1装置等离子体可见光波段轫致辐射功率的径向分布。
Using a multichannel quartz optical-fiber system calibrated with a standard tungsten strip lamp, the radial profiles of the visible bremsstrahlung radiation power in the HL-1 tokamak were measured.
介绍了原子高离化态研究装置,包括重离子加速器、测量装置、数据获取和处理系统。
A equipment of research of atomic high-ionized state is introduced, including heavy ion accelerator, instrument of measurement, data acquisition and data processing system.
在离子束溅射镀膜机的膜厚控制系统的研究中,由于采用了现代检测手段,使测量精度大大提高。
In the research of the membrane thickness control system of IBS plating machine, as having adopted modern detection means, measure precision improves greatly.
试验结果表明,硬件设计和软件系统的开发与集成满足了激光焊接光致等离子体电子温度和密度的测量要求。
Experiments results show that hardware design and software development meet the requirements for measurement of electron temperature and density of laser induced plasma.
建立了精确测量硫酸钙过饱和溶液在析晶过程中所有离子浓度变化的实验—计算系统。
They have established a precise measuring-calculating system to determine the variation of concentration for all species in the super saturated solution of calcium sulfate dihydrate (CSD).
离子能量自动分析器由多极型探头和计算机控制的测量系统组成。
The analyzer was composed of a multi plate probe and a computer controlled measurement system.
结果表明两级喇曼压缩系统配偏振干涉能有效抑制主束谐波影响,以更高时间分辨测量等离子体的更高密度区域。
The result shows that with the aid of the probe beam, the electron density can be probed with a much higher temporal resolution and the disturbance of harmonic can be effectively avoided.
通过两种方式的实验研究,检验了新型离子迁移试验测量系统的测量精度,验证了该系统具有很高的稳定性、可靠性以及很高的自动化程度,并具有极大的实用性。
We do the ion migration test for insulators by using the developed measuring system in our lab, it shows its high precision, high stability, reliability and automation with the great practicability.
在离子能谱测量中观察到双离子温度。产生这样电位分布的机制,归于会切系统中的斯托沫区和电子枪的不同工作方式。
The mechanism giving rise to such potential profiles can be attributed to the Stormer region in the cusp system and the different operation regimes of the electron gun used.
本文叙述了用多栅能量分析器测量静电堵漏会切系统中的离子积分能谱,从而得到离子温度、等离子体电位的原理和方法。
The ion temperature and plasma potential were measured by a multi-grid energy analyzer in an electrostatic plugging cusp system MM-4. The results show-that the plasma potential is?
这种系统特别适用于测量瞬变过程中的等离子体参量,从而成为等离子体微波诊断学中的一种有用手段。
This system is specially suitable for measuring the parameters of plasma transient process, and becomes a useful tool in plasma diagnostic with mi...
这种系统特别适用于测量瞬变过程中的等离子体参量,从而成为等离子体微波诊断学中的一种有用手段。
This system is specially suitable for measuring the parameters of plasma transient process, and becomes a useful tool in plasma diagnostic with mi...