仿真结果表明,电机转速比是影响交交变频轧机系统网侧基波功率因数与电流总畸变率的关键原因。
The simulation results show that the speed ratio of the motor mostly affects the total harmonic distortion of the current and the displacement power factor.
装置可以计算波形任意部分的多达50次的暂态谐波,给出谐波总畸变率及各次谐波的含有率和谐波值。
The device can calculate transient harmonics (up to 50 orders) of any part of data wave, give the total harmonic distortion, each harmonic ratio and each harmonic value.
通过实验结果表明,单级功率因数校正装置可以实现较高的功率因数、较低的总谐波畸变,而且输出电压纹波小。
Experiment results showed that the correction device of power factor could realize high power factor, low harmonic distortion and low ripple of output voltage.
实验结果表明,应用该电路拓扑的实验装置,其功率因数较高,输入电流的总谐波畸变较低,输出电压纹波小,而且整个装置的效率也比较高。
Experiment result showed, the topology can make the device get to high Power Factor (PF), low Total Harmonic Distortion (THD) of input current, low ripple of output voltage, and high efficiency.
在整周期采样的FFT算法的基础上,提出了确定基波周期的总谐波畸变(THD)最小的方法,并作了误差分析。
Based on the integer period sample FFT algorithm, a lowest total harmonic distortion (THD) method for determining the base period is proposed in this paper, and the derivation is theoretically given.
介绍进气总压畸变对双轴涡喷发动机性能和稳定性影响的试验及其结果。
A brief view and results of tests for the effects of the inlet total pressure distortion on the performance and the stability of a two-spool turbojet engine are presented.
在吊舱进气道进口安装扰流板进行试验,研究扰流板进气畸变的影响因素及总压畸变特征。
Characteristics and influence factors of total pressure distortion are studied based on tests conducted on a disturbed board installed in the nacelle inlet.
实验结果表明该原理样机能将功率因数提高到0.99以上,总谐波畸变小于7%。
The experimental results verify that the prototype can make the power factor reach over 0.99, and make total harmonic distortion reach lower than 7%.
给出了输入功率因数、畸变因子、峰值系数、总谐波畸变率和谐波分量的实验结果。
The experiment results show input power factor, distortion factor, crest factor, total harmonic distortion and harmonic components.
改型进气道减小了输出轴背风侧的分离和迎风侧的转弯损失,使其既保持了高总压恢复系数,且畸变指数最大降低了74%。
By modifying, the separation zone behind the shaft and turn loss at upwind side are all reduced. Modifying inlet maintains high pressure recovery, and the distortion index is reduced by 74% at most.
该方案能在80 ~ 265V宽输入电压范围内得到稳定直流电压输出,具有效率高、总谐波畸变率低、功率因数接近为1等特点。
It can achieve a fixed output of DC voltage in the universal input range of ac 80 ~ 265 V. It owns the advantages of high efficiency, low total harmonic distortion, PF near to 1.
试验表明其出口平均总压恢复系数较低,周向总压畸变指数较大,旋流较强且很不规则。
Test results show lower exit average total pressure recovery, larger circumferential total pressure distortion and stronger and more irregular secondary flow.
变唇口加杆可模拟具有中心高压区且周向畸变较小的总压分布。
The contour map of small circumferential total pressure distortion with high pressure area at centre can be simulated by the method of the combination of lip and rod.
介绍了1种分析进口总压畸变对多级轴流压气机特性影响的逐级模拟方法。
A stage - by - stage simulation method is introduced for analysis of inlet total pressure distortion effect on the multistage axial flow compressor characteristics.
本文通过数值计算的方法研究插板式总压畸变试验技术。
The numerical calculated method was used to research the technology of the total pressure distortion with flashboard.
在这种新的逆变器开关控制策略中建立多目标优化函数,既使得电压型逆变电路输出电流波形总谐波畸变率尽量小,同时又能减小逆变过程的电力电子开关损耗。
In this control law multi-object function is created, which enables a voltage-source type inverter to produce a near standard sine wave with a minimum switching loss.
该样机在实验中测得输入电流总谐波畸变率(THD)为4.26%,功率因数为0.998,达到了预期的设计效果。
Themeasured input current THD is 4.26%. Power Factor attains 0.998. Theprototype realizes the expectation.
该样机在实验中测得输入电流总谐波畸变率(THD)为4.26%,功率因数为0.998,达到了预期的设计效果。
Themeasured input current THD is 4.26%. Power Factor attains 0.998. Theprototype realizes the expectation.
应用推荐