全文为普通和双笼感应电机不对称短路的瞬态分析建立了理论基础。
All of these found the theoretical basis for the transient analysis of unbalanced short circuits for induction machine.
铜母线和母线支柱应能承受50千安及以上的三相对称短路电流所产生的电应力。
Copper busbar and busbar column should be able to sustain electric stress generated by electric current of three-phase symmetrical short-circuit of 50 kiloampere and above.
本文主要论述了电力系统中母线上发生三相对称短路时,其动稳定和热稳定的校验问题。
This paper discusses the short-circuit verifying of wires in dynamic stability and heat withstand while the wires are chosen in the design of power system.
目前大型汽轮发电机组轴系扭振特性的现场试验中广泛采用稳态不对称短路变频激振法。
Presently, the method of steady state unbalanced currents is widely used in the field test of torsional vibration characteristics of large-scale steam turbine generator rotor system.
本文首先根据系统发生三相对称短路时的短路电流,给出了三相矩形母线短路电动力的解析表达式。
The expression for short-circuit electrodynamic force of rectangular bus bars on the basis of the calculation of three-phase symmetry short-circuit current was fi.
此外,故障电压行波于非对称短路点发生线模与零模行波相互交叉透射,致使故障电压自然频率“混叠”。
In addition, line mode and zero-mode voltage wave cross each other at the point of fault which causes the natural frequency "aliasing".
使用矩阵运算代替对称分量法的传统序网故障变换,以实现不对称短路故障计算,并给出常见故障对应的参数矩阵。
Calculation formulas are proposed with matrices calculation to deal with unsymmetrical faults and parameter matrices for various faults are listed.
采用基于叠加原理的短路电流计算方法,克服了传统的对称分量法应用于配电网短路电流计算时所遇到的困难。
Furthermore, the superposition theorem is then adopted in the approach, which overcomes the difficulties when applying the symmetrical components to the short circuit calculation.
基于小波变换的分析方法,提出了基于定子三相电流之间相位对称度检测的定子绕组匝间短路故障在线检测新方法。
Based on wavelet transform, a novel on-line detection method is presented, which is based on the detection of symmetry degree among the stator three-phase line currents phases.
该判据可以对不对称的故障进行故障定位,这些故障包括单相接地故障、两相接地故障和两相短路故障。
The justifying conditions can be used to justify the location of faults, including single phase earthing, two phases earthing and two phases shorting.
通过分析低压隔爆电动机的主要故障类型,针对不对称性短路故障和断相故障提出了采用负序保护原理进行保护的方案。
Based on the analysis of main fault types of LV (Low Voltage) flameproof motor, the negative sequence protection principle is proposed for its asymmetric short circuit fault and open phase fault.
基于对异相短路的分析,发现两相电流故障分量波形呈现反向对称性,可利用相关分析法快速提取此特征。
The waveforms of the current fault component of two phases are symmetrical according to an analysis of wrong-phase-coupling. This characteristic can be quickly extracted by correlation analysis.
结果表明了PWM-FCL不但可以快速有效地限制住短路电流,并且在系统发生三相不对称故障时,可以保证故障线路非故障相以及非故障线路的正常运行。
The obtained results show that the PWM-FCL can limit the fault current quickly, and the unfaulted phase(s) and unfaulted line(s) will keep stable operation state when an asymmetry fault occurs.
以试验所用的故障模拟发电机为例,分别对发电机不对称运行和定子绕组匝间短路进行了故障特征计算。
The fault characteristics of stator winding inter-turn short -circuit and asymmetrical operation of generator are calculated for the fault simulation generator.
对于全并联直接供电牵引网短路故障,采用两相对称分量法,分析电路特征,得到短路阻抗表达式。
For the direct power traction systems with full parallel connection, the characteristics of short-circuit impedance is analyzed with method of two symmetrical phases, and the expression is acquired.
对于全并联直接供电牵引网短路故障,采用两相对称分量法,分析电路特征,得到短路阻抗表达式。
For the direct power traction systems with full parallel connection, the characteristics of short-circuit impedance is analyzed with method of two symmetrical phases, and the expression is acquired.