本文比较分析了各种测距算法,并在此基础上提出了一种同杆并架双回线的故障测距新算法。
This paper compares and analyses all sorts of fault location algorithms, and puts forward a new fault location algorithm for double transmission line on the same tower.
对两种极化电压下的横联差动电流方向保护的选择元件在同杆并架双回线故障下的动作行为进行了研究。
This paper analyses selectors of transverse differential current direction protection using two types polarizing voltage for double circuit lines on the same tower.
比较分析了各种主要的测距算法,并在此基础上提出了一种同杆并架双回线的故障测距新算法。
This paper compares and analyses various types of main fault location algorithms and puts forward a new fault location algorithm for double transmission lines on a same tower.
从理论上分析了同杆并架双回线跨线不接地故障时距离继电器测量阻抗的变化规律。
This paper analyses the rule of variations measuring impedance of distance relay when phase to phase fault occurs between two lines on double circuit line on the same pole (DLSP).
提出了同杆并架双回输电线路跨线故障定位的新算法。
A novel numerical algorithm of fault location estimation for two parallel lines on the same tower is presented in this paper.
提出了同杆并架双回输电线路跨线故障定位的新算法。
A novel numerical algorithm of fault location estimation for two parallel lines on the same tower is presented in this paper.