鉴于传统的电流互感器测试方法已经不适于校验新型的电流互感器,依据IEC标准和误差分析理论,提出了光电电流互感器的测试和校验方法。
Because the traditional calibrating method is not suitable for testing optical electric current transformer, a novel test system is designed based on the IEC standard and error analysis theory.
实验结果表明,由于光子计数器的核心器件光电倍增管及其高压电源不很稳定,光子计数器需要经常校验和标定。
Experimental results shows that the core device of the photon counter-PMT and it's high voltage power supply is not stable, the photon counter can be test and calibrated frequently.
实验结果表明,由于光子计数器的核心器件光电倍增管及其高压电源不很稳定,光子计数器需要经常校验和标定。
Experimental results shows that the core device of the photon counter-PMT and it's high voltage power supply is not stable, the photon counter can be test and calibrated frequently.