同时也考虑了变压器分接头对中低压侧电压的调整。
Voltage adjustment by transformer taps at medium_low voltage supply are also considered.
无载分接范围选择应能提供正确的低压侧母线电压。
No load tap ranges should be selected to provide an adequate low-side bus voltage.
配变和低压侧输电线路及其供给的用户群组成了配变台区。
An electrical transformer, transmission line on the side of low voltage and correlative users constitute the district of the electrical transformer.
低压侧瞬态过电压的形成有雷击和电子网暂态过程两种途径。
There are two ways to emerge instantaneous over voltage in the side of low voltage which are thunderstruck and instantaneous process of electronic network.
大、中型工厂变电所主变压器低压侧常采用单母线分段的运行方式。
The low voltage side of the main transformers in the substations of large and middle-sized plants USES operation mode in the single-bus sections.
硬件上通过双CPU系统结构,实现对低压侧数据信号的采集与计算;
The double CPU system is used in the data acquisition and calculation.
将谐波电流从低压侧的两相转换到高压侧的三相,建立谐波负荷模型。
Harmonic load model is established by transforming the harmonic currents from two-phase at LV side to three-phase at HV side.
运行优化方面主要是低压侧轴封供汽压力、轴封加热器和轴封冷却器的运行控制;
Run the operation under the control of optimizing aspect being that low pressure inclines shaft seal steam supply pressure , shaft seal heater and shaft seal chiller mainly;
通过对冰机低压缸低压侧浮环及其对应的污油捕集器采取相应的措施,保证冰机稳定运行。
Relative measures were taken to the floating ring on the low pressure side of LP cylinder and corresponding sludge oil collector, to ensure stable operation of the freezing machine.
阐述了对KSGZY系列移动变电站低压侧真空馈电开关机械维持机构的改造方法以及改造后的工作原理。
The reform steps and working principle of the mechanical holding apparatus of low voltage vacuum switcher in KSGZY series mobile substation are introduced.
通过测量用户低压侧三相电流相量,通过特定的算法处理,准确判定用户高计TA的实际变比是否与铭牌一致。
Through measuring three-phase current of low voltage at user side and handling by specific algorithm, TA ratio of HV measuring can be accurately judged whether is consistent with data plate.
随后利用电路理论对这种变压器的各种相间短路故障进行了分析,得到了各种故障情况下变压器高低压侧各相电流间的关系。
The relations between the currents of all phases and at both sides are drawn out by applying circuit theories and analyzing different inter phase short circuit faults of this kind transformer.
介绍了一例用助磁法测量大型变压器低压侧直流电阻的接线、仪器、测试过程和测试结果,讨论了助磁法运用于实际应注意的一些问题。
The paper introduces the saturable magnetic circuit method to measure the DC resistance of low voltage winding of large-size transformer with a practical application.
提供了一般低压配电网主电源侧短路电流计算的公式。
A formula for short current calculation in low voltage power grid distribution was put forward.
高电压电平漂移电路允许低压逻辑信号来驱动的IGBT在高达1200V一种操作高侧配置。
High voltage level-shift circuitry allows low voltage logic signals to drive IGBTs in a high side configuration operating up to 1200V.
系统的高、低压段被分成制冷剂侧、管壁、以及水或空气侧三个控制容积。
The high-pressure and low-pressure segments are divided into three control volumes, including the refrigerant inside tube, the tube wall and the fluid outside tube that is water or air.
系统高压侧产生如此低压强的最可能原因是制冷剂不足。
The most likely cause of such low pressure in the high pressure side of the system would be insufficient refrigerant.
系统高压侧产生如此低压强的最可能原因是制冷剂不足。
The most likely cause of such low pressure in the high pressure side of the system would be insufficient refrigerant.
应用推荐