• 一般情况下线路故障跳闸合闸越快,效果好。

    Under normal circumstances, line fault reclosing after tripping sooner, the better.

    youdao

  • 使用者继电器接地故障跳闸电流设置为高于最高值几毫安准确测量系统充电

    User is able to set the ground fault trip current of the relay just milliamps above the highest level, to accurately measure the system charging.

    youdao

  • 可以确保惟一跳闸保护装置就是故障点最近的装置。

    This ensures that the only protective device to trip is the one nearest to the fault.

    youdao

  • 线路出现故障继电保护使断路器跳闸,自动重合闸装置时间间隔后使断路器重新合上。

    That is, when the line failure, the relay circuit breaker tripping, the device auto-reclosing after a short time interval, so that a re-breaker.

    youdao

  • 继电保护隐藏故障造成输电线路连锁跳闸主要原因。

    Hidden failures of relay protection are the main cause of transmission lines cascading trips.

    youdao

  • 对于后备保护装置防止阻抗接地故障配置一只方向过电流继电器瞬时跳闸附件时间成反比

    For backup protection against high resistive ground faults, there will be a dual polarized directional overcurrent relay, inverse time with instantaneous trip attachment.

    youdao

  • 针对煤矿高压防爆开关综合保护装置主要存在短路故障越级跳闸漏电保护动作不准确问题进行深入研究

    This paper conducts a thorough research to the problem of short circuit override trip and inaccurate leakage protection action mainly existing in HV flameproof switchgear comprehensive protection.

    youdao

  • 最高系统安全性接地故障检测有助于避免充电电流造成的跳闸

    Maximum system security and immediate ground fault detection helps avoids nuisance tripping due to charging currents.

    youdao

  • 故障发生熔断器会断开,使所有故障电流流经跳闸线圈断路器断开

    If a fault occurs, the fuse ruptures diverting all the fault current through the trip coil, tripping the breaker.

    youdao

  • 为此提出了调度员在输电线路跳闸变压器跳闸母线故障变电站停电一些处理方法,并举例给予说明。

    In this paper, the author illustrates some treating methods for trip of transmission lines and transformers, bus failures as well as overall service interruption in substations.

    youdao

  • 变频器保护跳闸故障复位之前一直显示故障代码

    Inverter in protection tripping, after before the fault restoration will always show failure code.

    youdao

  • 电网发生故障根据断路器跳闸信息母线电压信息采用BFS(广度优先搜索)的方法搜索出故障区域

    When a fault occurs in a power system, fault area is located using Broad First Search (BFS) method by breakers and bus voltage message.

    youdao

  • 方法有效地避开了列车启动电流影响,不但可以迅速切除端的短路故障,而且通过延时跳闸还可以切除远端短路故障

    The nearby fault can be cleared immediately while the distant fault can be cleared with a delay by using the proposed method which will not be influenced by the starting current of trains.

    youdao

  • 方法降低网事故跳闸次数保证配网连续可靠运行减少配网线路故障巡查工作量具有重要意义。

    It is of great significance to decrease fault-trip times, assure reliable operation and lessen inspection workload for distribution systems.

    youdao

  • 本文变频器电流跳闸过载跳闸故障原因进行了分析,介绍了如何判断的具体方法。

    This paper analyzed the reason of trip for over current and overload in VVVF. And introduced how to determine on these fault.

    youdao

  • 继电保护装置反应电力系统故障不正常运行状念,并动作于断路器跳闸发出信号的设备。

    Relay protection is one of device to respond the fault and abnormal circulate situation of electric power system, to make the breaker action and to send out the signal.

    youdao

  • 并联跳闸装置- - -一旦控制装置监测故障发生电流过载,将自动切断所有连接热水器所有电源最大限度保护热水器。

    Shunt trip disconnecter - provides maximum protection by interrupting all power to the system in the event of a control sensed malfunction or overcurrent.

    youdao

  • KA5跳闸报警继电器。设备产生偏励磁可控硅故障电流故障时,KA5合,断路器分励线圈得电跳闸切断电源

    When there are bias excitation, controllable silicon failure, over current and other failures, KA5 gets absorbed and breaker loop trips by powered on so as for switching off main power supply.

    youdao

  • GFCI提供电源电源线路PCB(122)电路连接,切断由于故障测试跳闸GFCI的那些电路的电源。

    The power lines that supply the GFCI with power are also coupled to the circuits on the PCB (122) to disconnect power to those circuits of the GFCI that trips due to faults or tests.

    youdao

  • 实验室试验证明系统单相故障状态准确可靠检测故障线路驱动跳闸

    The lab experiments showed that under the single phase fault status, the system could be accurate and reliable to detect the fault line and to drive the trip.

    youdao

  • 针对连锁故障快速相继开断阶段,提出用于研究输电设备负荷连锁跳闸问题的相继故障演变模型

    In view of fast continual outage stage, a continual fault evolution model used to study cascading outages for electric transmission equipment's over load was proposed.

    youdao

  • 通过江陵换流站交流滤波器开关跳闸故障原因分析发现GIS组合电器存在的重大隐患,提出初步解决办法

    Through the cause analysis on the trip fault of AC filter breaker of Jiangling Converter Station, the hidden risk in GIS equipment was discovered. The tentative resolving measure was raised.

    youdao

  • 线路距离保护段范围发生故障时,利用对侧开关跳闸时序电流的突变量加速侧保护跳闸改善保护的性能

    This paper presents a novel approach to accelerated trip of power transmission lines by using biorthogonal wavelet transform to improve the performance of protection relays.

    youdao

  • 线路距离保护段范围发生故障时,利用对侧开关跳闸时序电流的突变量加速侧保护跳闸改善保护的性能

    This paper presents a novel approach to accelerated trip of power transmission lines by using biorthogonal wavelet transform to improve the performance of protection relays.

    youdao

$firstVoiceSent
- 来自原声例句
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定