控制电路从单相接地电压计算得出相间电压。
The control circuit calculates the phase-to-phase voltages from the phase-to-ground voltages.
时钟电路被配置为响应于具有输入供电电压和接地电压的时钟信号向内部节点提供上拉电流。
The clocking circuit configured to provide the pull-up current to an internal node in response to a clock signal having the input supply voltage and the ground voltage.
这样通过延伸机组的接地网进一步降低接地电阻,使雷电流迅速流散入大地而不产生危险的过电压。
Therefor by earthing connected net of set, it reduce earthing resistance, make the electricity discharge in earth prompt without dangerous overvoltage.
对于中性点不直接接地的发电机,由于三相对地电容值存在差异,中性点与地之间存在一定电压。
Due to three-phase capacitance to ground, certain voltage exists between the neutral and the ground for a generator with ungrounded neutral.
电气设备的接地部分与大地零电位点之间存在对地电压。
There is voltage to ground between ground part of electric equipment and point of zero electric potential of earth.
介绍一种新颖的数据采集系统,它用红外遥测技术间接地将远地电压监测仪表中的数据送入计算机处理。
A kind of new data acquisition system is presented. It transfers data from the remote voltage sampling meters to computer with the help of infrared remote measuring technique.
在我国北方高寒冰冻地区接地系统的接地电阻季节系数可达3.0,接触电压和跨步电压季节系数可能达到10和5.4。
The seasonal coefficient of grounding resistance possibly reaches 3.0 in freezing region of North China, and those of touch voltage and step voltage 10 and 5.4, respectively.
在中性点不接地电网中,频繁发生由电磁式电压互感器引起的铁磁谐振现象。
In the neutral ungrounded power system, ferroresonance over-voltage due to electromagnetic transformer takes place frequently.
变电站避雷器安装位置和数量及输电线终端塔的接地电阻对雷电过电压有著直接的影响。
The location and quantity of arrestor and impulse grounding resistance of towers has direct influence on lighting overvoltage.
分析了中性点接地电容器组内部故障时的内部过电压和相电流变化,并给出了相应计算公式。
This paper analyses the internal overvoltage and the phase current of grounded wye shunt capacitor bank when there are failures in it, and gives corresponding equations.
为减少产生谐振,降低内过电压,中性点接地电阻器在中压电网的应用越来越多。
For decrease of harmonics and switching overvoltages the application of neutral grounding resistors is spreed.
采用数值计算方法分析了垂直接地极对接地系统的接地电阻、接触电压及跨步电压等的影响。
The influences of vertical grounding electrodes on grounding resistance, step and touch voltages were analyzed numerically.
减小接地故障点的残流有利于接地电弧的瞬间熄灭及降低间歇性电弧接地过电压。
The reduction of the residual current of the ground-fault point is beneficial to the extinction of the grounding arc and to the reduction of the intermittent arc grounding over voltage.
季节因素将影响地网的安全性能,导致地网的接地电阻、接触电压和跨步电压的改变。
The seasonal factor affects the safety of grounding system, and causes changes in the grounding resistance, the step and touch voltages on the ground surface above the grounding system.
在中性点非直接接地电网中,单相接地及由电压互感器(PT)引起的谐振过电压均是多发性的事故。
In ungrounded distribution system the single-phase-grounding and the ferro-resonance caused by the PT (Potential Transformer) are of the frequent accidents.
在零地电位接地网的范围内建设同级电压的发电-用电系统,可保证在该接地网内工作人员的人身安全。
When power generation and power consumption system with same voltage class is built within the bound of ground grid with zero ground potential, operators safety in the ground grid can be ensured.
利用该统一模型,分析了外加直流电压法、外加交流电压法、乒乓切换法中电刷接触电阻对励磁绕组接地电阻测量值的影响和危害。
By using power of DC superimposed AC, oxidation rate rose with increase of voltage but had nothing to do with frequencies in this experiment.
利用该统一模型,分析了外加直流电压法、外加交流电压法、乒乓切换法中电刷接触电阻对励磁绕组接地电阻测量值的影响和危害。
By using power of DC superimposed AC, oxidation rate rose with increase of voltage but had nothing to do with frequencies in this experiment.
应用推荐