结果表明,椎体后高、椎体上矢径呈正异速生长。
The results show that posterior height of vertebral body and Upper antero-posterior diameter of vertebral body are positive allometry.
椎体后缘有骨性缺损,缺损边缘硬化。
There were bony defect and sclerosis on the vertebral body edge.
此次实验研究的是单个椎体的螺钉拔出力。
This experiment researched the drawn force of the single centrum pedicle screws.
严重病例可能需要脊髓减压和椎体稳定性手术。
Severe cases may respond to surgical spinal cord decompression and vertebral stabilization.
从右侧数第二块椎骨显示出更明显的椎体受压。
The second body from the right shows a greater degree of compression than the others.
结果91例病例,有336个椎体见压缩性骨折。
Results in 91 cases, compression fractures was found in 336 centrum.
关节突关节是位于脊柱背侧两个椎体间的一对小关节。
Facet joints are pairs of small joints between the vertebrae in the back of the spine.
小关节突关节不对称的滑移会导致椎体滑移出现旋转。
Asymmetrical slip of the facets results in a rotational component to the spondylolisthesis.
目的:评估椎体整块切除大根动脉损伤后的神经功能。
Objective. To assess neurologic function after interruption of the artery of Adamkiewicz in TES.
退行性椎体滑移是腰椎活动节段长时间节段间不稳定的结果。
Degenerative spondylolisthesis is the result of longstanding intersegmental instability at the lumbar motion segment.
目的研究椎体终板在脊柱前路椎体间植骨融合手术中的作用。
Objective To study the role of endplate in anterior interbody spinal fusion.
“椎体融合术”就是将两个脊椎连接起来防止脊椎不稳定的手术。
An "interbody fusion" is a bony bridge that "welds" the two vertebral bodies together to stop unstable motion.
有许多途径用于作椎体扩张术,包括椎体成形术和后凸成形术。
There are many approaches to vertebral augmentation surgery, including vertebroplasty or kyphoplasty.
让我们在您的整个脊椎每个椎体而受到影响你的身体起伏的议案。
Let each vertebrae in your entire spine be affected by the undulating motion of your body.
目的:本文目的是探讨椎间关节间距与儿童椎体滑脱之间的关系。
Objective. The purpose of this article was to explore the relationship between interfacet spacing and pediatric spondylolysis.
椎间盘变性是否是退行性椎体滑移的病因,证据上还存在着矛盾。
There are controversial evidences about involvement if disc degeneration in etiology of DS.
目的:评估椎体加强术联合棘突间减压装置在同一病例中的应用。
Objective. Evaluation of vertebral augmentation combined with interspinous decompression procedure in the same sitting.
目的:本试验的目的是论证经皮椎体成形术中骨水泥量的安全范围。
Objective. The aim of this study was to demonstrate the safe range of cement volume during percutaneous vertebroplasty.
词变得越来越大——这种情况在椎体变得不稳定并开始滑脱的时候发生。
The words are getting bigger and bigger –this condition occurs when vertebra become unstable and start slipping.
就作者所知,这是首次描述对颈椎血管瘤以气球囊椎体后凸成形进行治疗。
To the authors' knowledge, this is the first description of cervical hemangioma treated by balloon kyphoplasty.
研究设计:前瞻性随机实验研究,一猪模型腰椎前路椎体间融合实验研究。
Study Design. Prospective and randomized experimental study with anterior lumbar interbody fusion in a porcine model.
目的:观察椎体成形术中犬的血液动力学和血气变化及是否发生肺脂肪栓塞。
OBJECTIVE: To observe the hemodynamic and blood gas changes and whether there is the pulmonary fat embolism in the vertebroplasty.
目的:对椎体成形术后新发椎体压缩骨折特点及相关的危险因素进行调查研究。
Objective. To investigate the characteristics and associated risk factors of new-onset vertebral compression fractures after vertebroplasty.
背景:据我们所知,没有对在老年患者行后路椎体间融合术的手术结果任何报告。
BACKGROUND: We are aware of no reports on the surgical results of posterior lumbar interbody fusion in elderly patients.
疼痛能在两下肢间转移是由退行性椎体滑移引起的椎管狭窄的一个最典型的症状。
One of the most characteristic symptoms of DS with stenosis is leg pain that shifts from side to side.
目的:旨在研究两个胶原蛋白交联剂对于手术后椎体关节失稳恢复机械性能的能力。
Objective. To investigate the ability of two collagen crosslinking agents to restore mechanical properties to lumbar joints destabilized by surgical decompression procedures.
诱发因素包括许多:创伤、凝血病、动静脉畸形破裂、椎体血管瘤、高血压以及妊娠。
Many causative factors have been implicated including trauma, coagulopathies, rupture of arteriovenous malformations, vertebral body hemangiomas, hypertension, and pregnancy.
传统播音系统使用的大型扩音器中的椎体振动较为缓慢,使声音更加适合人类听觉范围。
The cones of larger loudspeakers used in traditional public-address systems vibrate more slowly, making them better suited for sounds in the range of human hearing.
目前的器械设计各不相同,带有干扰终板的突起的器械存在椎体损害相关并发症的可能。
While the current devices differ in design, those devices with keels violating the endplates present the risk of complications associated with vertebral body damage.
目前的器械设计各不相同,带有干扰终板的突起的器械存在椎体损害相关并发症的可能。
While the current devices differ in design, those devices with keels violating the endplates present the risk of complications associated with vertebral body damage.
应用推荐