提出了一种在带有反转平台的精密离心机上标定陀螺加速度计误差模型二次项系数K 2的D -最优试验方案。
D-optimal test scheme was presented for calibrating second-order coefficient K2 of PIGA (Pendulous Integrating Gyro Accelerometer) error model on a precision centrifuge with counter-rotating platform.
利用MATLAB进行了仿真,使得在三轴转台上标定加速度计动态误差系数有了清晰的先验认识和结果预期。
As the result of simulating finished with MATLAB, clear prior knowledge and anticipated result of calibrating dynamic error coefficients of accelerometer on three-axis turntable are obtained.
提出了一种在不带有反转平台的精密离心机上标定陀螺加速度计误差模型系数的两位置测试方法。
The paper presented a two-position test method for calibrating error model coefficients of PIGA (pendulous integrating gyro accelerometer) using precision centrifuge without counter-rotating platform.
阐述了所提方案的测试原理,并提出分离和精确标定陀螺加速度计误差模型系数的数据处理方法。
Its testing principle was expounded, and a data processing method for separating and accurately calibrating error model coefficients were presented.
阐述了所提方案的测试原理,并提出分离和精确标定陀螺加速度计误差模型系数的数据处理方法。
Its testing principle was expounded, and a data processing method for separating and accurately calibrating error model coefficients were presented.