小电流接地系统发生单相接地故障时,故障线路与健全线路在特征频段内零序电流的相位差别是接地选线判据的重要依据之一。
The phase comparison between fault feeder and healthy feeder is one of important criteria in fault line selection for neutral non-effective grounding systems.
在典型的六相输电系统中,半正序、半零序和半负序故障分量不受系统阻抗变化的影响。
In typical six-phase transmission system, half positive sequence, half zero sequence and half negative sequence fault components are independent of the variance of system impedance.
输电线路的零序参数尤其是多回互感线路的零序参数是电力系统继电保护整定计算需要的重要参数,所以其准确测量具有重要意义。
The zero-sequence parameter of transmission lines especially of transmission lines with mutual inductances is of great important in the relay protection setting calculation of power system.
由于只用到暂态零序电流量,该选线判据不受PT异常情况的影响,可以适用于任意方式的不直接接地系统。
For that the transient zero sequence currents are used only, the criterion is immune to the abnormity of the PT, and it can be applied to all kinds of the neutral indirectly grounded systems.
将提取的暂态零序电流故障特征作为条件属性,信号增强倍数作为决策属性,构成一个决策系统。
The extracted fault characteristics of transient zero sequence current is looked as condition attributes and the multiple of signal enhancement is.
配合SD - LJD (LXK)系类零序电流互感器和动作继电器即组成完整的零序(接地)保护系统。
Used together with SD-LJD (LXK) series ZCT and executing relay to form a complete zero sequence (ground) protection system.
根据这一特点,对小电流接地系统中线路的零序参数相频特性进行研究,得出系统发生单相接地故障时不同频带上暂态零序电流特性。
The zero-sequence angle-frequency characteristic of the lines are studied based on it and the characteristics of transient zero-sequence current in different frequency ba.
分析表明,即使系统不存在零序回路,DVR都会在补偿控制中向系统注入微小的零序分量,该零序分量会对无零序回路系统侧电压造成不良影响。
It shows that DVR will inject small zero sequence component into the power system during compensation control even if there is no zero sequence circuit. This will influence the voltage on system side.
然后对小电流接地系统单相接地时零序电容电流的暂态过程及特点做了介绍和分析。
Subsequently, the transient course and characteristics of zero sequence capacitive current are introduced and analyzed.
实验结果表明,该装置可对三相四线制系统中的谐波、负序、零序等电流分量进行补偿。
Experimental results prove the proposed control method can compensate the harmonic, negative sequence and zero sequence current components in the three phase four wire.
输电线路的零序参数尤其是多回互感线路的零序参数是电力系统继电保护整定计算需要的重要参数,所以其准确测量具有重要意义。
The incremental method, differential equation method and integral equation method are three main methods in zero-sequence parameters on-line measurement of transmission lines with mutual inductance.
小电流接地系统发生单相接地故障时,对零序分量而言,非故障线路相当于空载。
The healthy line is unloaded for zero-sequence component when a single-phase fault occurs in a non-solid earthed network.
为此,提出了新的控制策略,该控制策略通过检测并消除指令中的零序分量,以破坏无零序电流回路系统的零序电压正反馈条件,消除DVR注入零序电压的不良影响。
So a new control strategy is proposed to detect and suppress the influence of zero sequence component injected by DVR. Simulation results show that the proposed strategy is co…
为此,提出了新的控制策略,该控制策略通过检测并消除指令中的零序分量,以破坏无零序电流回路系统的零序电压正反馈条件,消除DVR注入零序电压的不良影响。
So a new control strategy is proposed to detect and suppress the influence of zero sequence component injected by DVR. Simulation results show that the proposed strategy is co…