单相电容运转电机配置热过载保护。
Single phase capacitor run motor with thermal overload protection.
主要用于低压单相电源系统电子电器设备的过电压保护。
Voltage protection for electronic and electrical equipment used in low voltage single phase power supply system.
针对单相重合闸与三相重合闸时系统振荡的特点,提出了新的距离加速保护方案;
In allusion to the characters of system oscillation during single-phase recloser and three-phase recloser, the author put forward a new distance protection accelerating scheme.
分析井下供电系统单相接地的危害,介绍几种常见的漏电保护方法。
This Paper analyses the harm of single-phase earthing in electricity supply system of mine and introduces several type of common ways of leakage protection.
针对中性点经消弧线圈接地的小电流接地系统,设计了一套单相接地补偿及选线的微机保护装置。
Aim at an-arc suppression reactor earthing power system, we design a suit of microcomputer system for compensating single-phase earthing current and selecting line.
针对中性点经消弧线圈接地的小电流接地系统,设计了一套单相接地补偿及选线的微机保护装置。
Aim at an-arc suppression reactor earthing power system, a suit of microcomputer system for compensating single-phase earthing current and selecting line was designed.
介绍了基于“S注入法”的小电流接地系统单相接地故障选线定位保护。
The protection for earth fault line selection and fault point location by S injecting current in neutral isolated power system is presented.
设置有容易替换的电线支承件或保护帽,以提高从一单相传输结构到一三相传输结构的可变换性。
It is provided with easily replaceable wire support members or protective caps to enhance convertibility from a single phase delivery configuration to a three phase delivery configuration.
数字式变压器差动保护在星形侧发生外部单相接地或线路单相遭雷击的情况下,差动保护有时会误动。
Digital transformer differential protection may falsely take effective when external single-phase earth fault occurs at star side or the line endures lightning strike on single phase.
通过发电机定子接地保护之间的相互配合,在整个发电机定子绕组范围内发生单相接地故障时,发电机定子接地保护均能灵敏地动作。
Through cooperating each other between the generator stator ground protection, it can operate sensitively when single phase ground fault in whole range of generator stator winding occurs.
在高温、高电流运行的情况下,单相电机都受到一个内置式、自动重置热过载保护装置的保护。
Single phase motors are protected against both high operating temperatures and high current by a built in, automatically resetting thermal overload.
进而提出了基于多回路-有限元耦合数学模型的同步发电机定子单相接地故障三次谐波电压保护方案校验方法。
Furthermore, a checkout method for the third harmonic voltage based protection scheme of stator ground fault in generators is presented based on the verified MLM-FEM coupled model.
将该文提出的判别方法用于处理小电流单相接地故障保护的现场试验数据,获得了好的效果。
This method has been applied to analysis of field test data of small current fault relaying, and obtained good results.
本文将基于故障分量的继电保护原理用于单相接地故障定位。
This paper introduces principles of relay protection based on the fault component and applies these to the fault location.
因此,自适应判据有效提高了保护在定子绕组经过渡电阻单相接地情况下的灵敏度。
Thus, the proposed adaptive criterion can effectively improve the sensitivity of generator protection is improved while the single-phase of stator winding is grounded via transition resistance.
因此,自适应判据有效提高了保护在定子绕组经过渡电阻单相接地情况下的灵敏度。
Thus, the proposed adaptive criterion can effectively improve the sensitivity of generator protection is improved while the single-phase of stator winding is grounded via transition resistance.
应用推荐