介绍了海拔高度和大气条件对高压产品外绝缘试验电压的影响及影响机理。
In the paper the influences of altitude and atmosphere condition on external insulation test voltage are introduced, and the effect mechanisms are analyzed respectively.
50KV采用计算机控制,通过人机对话方式,完成对绝缘介质的工频电压击穿,工频耐压试验。
ZJC-50KV controlled by computer, through the man-machine dialogue mode, the voltage breakdown insulation, power frequency withstand voltage test.
采用计算机控制,过人机对话方式,完成对、绝缘介质的工频电压击穿,工频耐压试验。
Using computer control, man-machine dialogue mode, the completion of the power frequency voltage breakdown of insulation media, power frequency withstand voltage test.
针对不均匀电场(棒-板间隙)中绝缘板上残余电荷对50%冲击闪络电压u _(50)的影响做了一些试验研究。
The effect of charges remaining on a dielectric plate upon the 50% impulse surface flashover voltage U_ (50) in the non-uniform field (rod-plane gap) is investigated.
ASTM D149固体电绝缘材料在工业电源频率下的介电击穿电压和介电强度的试验方法。
Standard Test Method for dielectric breakdown voltage and dielectric strength of D149 ASTM solid electrical insulating materials at industrial power frequencies.
本文提出了一种基于直接冲击电压对电器绕组匝间绝缘的试验方法。
A test method for insulation between coils of electrical equipment based on directly impulse voltage are presented.
根据XLPE绝缘电缆用直流电压进行现场试验的经验,要求开发新的方法。
There exist major defects in conventional site tests of XLPE insulated cables with DC voltage, therefore, a new method with better testing results must be found.
单只线圈制造完成后,在下线前应经过匝间耐电压试验,以保证匝间绝缘质量。
After coil manufacturing, the coils shall be treated with inter-turn voltage withstanding test to ensure the inter-turn insulation quality before inserting coil.
分析了高电压直流耐压试验可有效发现纸绝缘电缆缺陷,但在发现交联聚乙烯绝缘电力电缆缺陷方面有局限性。
The HVDC withstand voltage test can discover the defect of paper insulated cable efficiently, but it has limitation in discovering the defect of cross-linked polyethylene insulated power cable.
ASTM D149固体电绝缘材料在工业电源频率下的介电击穿电压和介电强度的试验方法。
Test method for ASTM D149 solid electrical insulating materials at commercial power frequencies the dielectric breakdown voltage and dielectric strength.
直流电压试验作为一种对油浸纸绝缘电缆非常有效的方法应用至今,但它对塑料绝缘电缆是无效而且有害的。
The DC test, which is an effective means for the diagnostics of oil impregnated paper insulated cable, is still used even now, but it is ineffective and harmful for the plastic insulated cable.
本文提出了绝缘材料对模块绝缘电压产生影响的试验方案,分析、讨论了试验结果,得出了一些重要结论。
This paper proposes a test plan that isolation material affects modul isolation voltage and analyzes the test results. In this paper sone important conclusions are inferred.
介绍了一种由冲击电压发生器和峰值电压表组成的用于电机磁极线圈匝间绝缘试验的设备,详细说明了设备的工作原理及关键技术,给出了试验结果。
The paper introduces a type of the turn-to-turn insulation test equipment including an impulse-voltage generator and a peak voltmeter for the electrical machine pole coil.
交流耐压试验是交流电气设备最重要的试验项目,是考验被试品绝缘承受交流电压能力的有效方法。
AC Withstand Voltage test is the most important test item to AC electric equipments, is a valid method of trying out the ability of the insulation withstanding AC voltage of tested object.
本标准适用于交流发电机、同步调相机和交流电动机定子线圈及绕组绝缘交、直流耐电压试验。
The standard is applicable to stator coil and winding insulation alternative and direct current voltage withstanding test for AC generator, synchronous phase modifier and AC motor.
本标准适用于交流发电机、同步调相机和交流电动机定子线圈及绕组绝缘交、直流耐电压试验。
The standard is applicable to stator coil and winding insulation alternative and direct current voltage withstanding test for AC generator, synchronous phase modifier and AC motor.
应用推荐