• Describes a method to detect the edge of omnidirectional M-mode echocardiography images.

    提出全方向M型心动图边界提取方法

    youdao

  • Using two dimensional guided M-mode echocardiography we determined cardiovascular parameters.

    及M型超声心动测定有关心血管参数。

    youdao

  • An omnidirectional M-mode echocardiography system and its clinical practices are introduced in this paper.

    文中介绍了全方向M型心动图系统的实现临床应用

    youdao

  • The paper studies the method of boundary detection in omnidirectional M-mode echocardiography based on a sub-pixel technique.

    研究一种基于亚象素技术的全方向M型心动图边界检测方法

    youdao

  • It is rather preferable to monitor PCWP by M-mode echocardiography, so that the diastolic pressure of pulmonary artery may be given.

    表明可用超声心动图监测肺毛细血管嵌入从而亦可了解肺动脉舒张压。

    youdao

  • The system also can show a lot of omnidirectional M-mode echocardiography with ECG synchronously, that is rebuild from 2d echocardiography.

    系统可以提取2心动图下方心电图全方向M型心动图同步显示

    youdao

  • Objective To confirm clinical significance of wall motion velocity and acceleration measured by LEJ-1 omni-directional M-mode echocardiography (OME).

    目的证实LEJ - 1型全方向m -型超声心动图测量心室运动速度加速度临床意义

    youdao

  • Methods This study consisted of 102 patients and 36 healthy volunteers. VP was measured by color M-mode echocardiography from the apical four chamber view.

    方法选择原发性高血压病人102例健康志愿者36例,在心尖心切面,应用彩色M型多普勒超声测量VP

    youdao

  • Objective To assess left ventricle(LV) systolic function in acquired immunodeficiency syndrome(AIDS) patients with two dimensional and M-mode echocardiography.

    目的应用M-型超声心动图技术评价艾滋病患者心室收缩功能的变化。

    youdao

  • The paper presents a method of motion curve frequency domain filtering in Omni-directional M-mode echocardiography images based on Discrete Fourier Transform (DFT).

    介绍基于离散傅里叶变换(DFT)全方向M型超声心动图运动曲线滤波技术。

    youdao

  • The edge of all-directional M-mode echocardiography images is the combination of the cross points of the sample line and the boundary between the blood and the heart by the time.

    全方向M型心动图边界采样线血液腔室壁组织结构形成的分界线与采样线交点位置变化的时间展开。

    youdao

  • Echocardiographic features of mitral leaflet motion in 86 patients with heart diseases were studied with M-mode echocardiography and compared them with that of 20 normal subjects.

    本文以M型超声心动图研究86心脏病患者二尖瓣运动20例正常人比较

    youdao

  • Two dimensional image was obtained by transesophageal echocardiography. The thickness, wave time and velocity were showed during atrial septal motion by omni directional M mode echocardiography (OME).

    应用经食管超声心动图获得图像,全方向M超声显示测量房间隔运动厚度波幅时间速度

    youdao

  • The cardiogram was studied by echocardiography specialists by color m mode Doppler echocardiography.

    采用M彩色多普勒超声心动图进行研究。

    youdao

  • Transesophageal echocardiography with two dimensional image, M-mode and pulse Doppler were performed at baseline and after several episodes of de.

    使用食管超声心动图电除颤前后记录、M型勒超声图像

    youdao

  • Objective To evaluate left atrial function by 2-de, M-mode and pulsed Doppler echocardiography in different patterns of left ventricular geometric models.

    目的联合应用二维、M -型超声心动图脉冲多普勒技术评价高血压心室不同构型功能改变。

    youdao

  • Under the m mode of echocardiography end diastolic left ventricular internal diameter left ventricular posterior wall thickness and interventricular septal thickness were determined.

    超声心动描记法为M型模式测定舒张末期直径、左室厚度及室间隔厚度左室射血分数。

    youdao

  • EDV, ESV, and LVEF were calculated using Simpson's rule algorithm for monoplane LV angiography, using M-mode method for two-dimensional echocardiography.

    造影采用单平面法(辛普森法则),二维超声心动图采用M型超声获得EDVESVLVEF

    youdao

  • Methods The right cardiac structure and function were measured by using M-mode and two-dimension echocardiography in 50 OSAS patients.

    方法二维多普勒超声心动图测定50例osas患者结构功能

    youdao

  • Objective To evaluate the value and accuracy of M-mode color Doppler echocardiography for detecting left ventricular diastolic function in patients with cardiac disease.

    目的探讨彩色M彩色多普勒超声评价心室舒张功能价值准确性

    youdao

  • Objective To evaluate the left ventricular diastolic function in the patients with hypertension by color M-mode Doppler echocardiography(CMM) and Doppler Tissue Imaging(DTI).

    目的:应用彩色M型多CMM组织多普勒成像(DTI)等方法评价高血压患者舒张功能,探讨CMM和DTI评价左室舒张功能的临床价值。

    youdao

  • Color m mode Doppler echocardiography studies were obtained from mitral valve orifice toward the apex: the rate of flow propagation velocity (FPV) from apical 4 chamber views.

    m取样线置于二尖瓣左室流入道心尖获取彩色左室舒张期血流传播图测量fpv。

    youdao

  • Color m mode Doppler echocardiography studies were obtained from mitral valve orifice toward the apex: the rate of flow propagation velocity (FPV) from apical 4 chamber views.

    m取样线置于二尖瓣左室流入道心尖获取彩色左室舒张期血流传播图测量fpv。

    youdao

$firstVoiceSent
- 来自原声例句
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定