这个试管是一个毛细管粘度计的组成部分,该粘度计是用来测量液体粘度的。
The tube formed part of a device called a capillary viscometer used to measure viscosities.
倾斜所选择的锭子,将其倒到涂层的试样上并小心地附着在粘度计上。
Tilt the selected spindle, slide it into the coating sample and carefully attach it to the viscometer.
降低粘度计直至凹槽在定子的轴正好接触到涂料上,并重新检查其水平。
Lower the viscometer until the grooves on the spindle shaft just touches the coating, and recheck the level.
将粘度计放在可调整的架子上并降低它到能使锭子在合适的深度。保证仪器的水平状态。
Place the viscometer on its adjustable stand and lower it to the level that will immerse the spindle to the proper depth. Make sure the instrument is level.
(新英)新型旋转粘度计快速、有效、准确地测量粘度,提供理想的解决方案,它易于使用,适用范围广,可用于各种液体的检测。
Sheen new digital adhesion meter fast, effective and accurate measurement of viscosity, provides an ideal solution, it is easy to use, wide application, can be used for detection of various liquids.
本文提出了一个在GPC -粘度计联用实验中,用单一多分散待测试样进行特性粘度标定时的加宽改正新方法。
A broadened correction method using only single polydispersed polymer sample at the intrinsic viscosity calibration in the experiment of GPC combined with viscometer.
介绍最近美国某聚酰胺生产厂在在线粘度计监测下,提高聚合反应工艺水平的方法。
A method improving the polymerization efficiency with in-line viscosity monitoring used by an American polyamide producer is introduced.
目的:对锥板式粘度计测定血液粘度的重复性及一些影响因素进行实验观察。
Objective: To study the testing repeation and inf'luential factors in the blood viscosity testing with the cone and plate viscometers.
采用锥板粘度计研究了聚酰胺酸溶液的流变性能及其粘度的影响因素。
The rheological behavior of polyamic acid solution and the influential factors on its viscosity were studied with a cone-plate rheometer.
介绍双螺杆挤出机的最新进展以及反应性挤出生产线控制技术开发动向;详述粘度计在反应性挤出工艺中的应用。
The new progress about twin—screw extruders and control technology in reaction extrusion line are described. Some applications of viscometer in this processing technology are introduced too.
DV - E低成本数字粘度计为世界上的粘度测量设定了一个标准。
The Brookfield DV-E has set a world standard for value in viscosity measurement.
利用毛细管粘度计测量流变性时,应考虑影响测量精度的几个主要因素。
When measuring rheology with capillary viscometer, several factors which may affect on measuring precision shall be considered.
此过程描述了用粘杯粘度计来测量涂料粘度的方法。
This procedure describes the assessment of paint viscosity using a Zahn viscosity cup.
同时,文章还介绍了怎样用旋转粘度计准确测定卡森液体的流变参数。
How to measure properly the rheological parameters of Casson fluids by rotary viscosimeter is discussed also in this paper.
强调了在标准粘度液证书中应给出不同温度下的运动粘度和粘度值,以满足粘度计检定工作的需要。
It was stressed that the kinematic viscosity and viscosity should he given at different temperatures in the certificate of the standard viscosity liquid to meet the need of the verification.
本文介绍了一种新改进的常亮式光电旋转粘度计。
In this article the author gives an account of his newly renovated slag viscosimeter.
为了阐明转变的性质,用毛细管流变仪和微型平板粘度计研究了其熔体粘度的温度依赖性。
In order to clarify the nature of the transition, the changes of melt viscosity with temperature and shear rate were investigated by capillary rheometer and micro-parallel type rheometer.
采用毛细管粘度计考察了稳定剂对石油沥青质溶液粘度性质的影响。
The effect of stabilizers on viscosity behavior of petroleum asphaltene solutions was studied with a capillary tube viscosimeter.
介绍了一种落球式粘度计,具有结构简单、实用的优点,可以应用于需要对粘度进行反馈控制的自动化装置。
A simple and practical falling-ball viscometer, which can be applied into the automatic instrument with the need of viscosity control are introduced.
油墨粘度计:量度印刷油墨粘度的仪器。参阅粘度。
Inkometer: An instrument for measuring the tack of printing ink. See tack.
用旋转粘度计对新拌水泥浆进行了动态检测,低需水量水泥的新拌水泥浆具有良好的流变性能,同时它的流变模型符合宾汉姆流变模。
Through dynamic testing on fresh paste by rotatative viscosimeter, The fresh low water demand cement has good rheology behavior, and its rheology behavior conformed to Bingham model.
用旋转粘度计法研究了掺加不同高效减水剂的新拌水泥浆体的流变性能。
Stirring viscosimeter is employed to research the rheological property of fresh cement paste with different superplasticizers.
设计的锥板粘度计由产生不同切变率的机械传动装置、放置血样的试样杯和锥板等装置组成。
The viscometer was composed of mechanical rotating parts creating different shear rate, a sample cup and a cone plank.
粘度是淀粉浆的最重要的流变性质。本文介绍了淀粉浆粘度测定中常用的粘度测定方法及所用粘度计的特性及使用注意事项。
Viscosity is the most important rheology property of starch. In this article, we introduce several viscosity determinations and the characteristics of viscometers of stach in common use.
样品处理直接从压力容器或者通过压力发电机,这要比其他高压粘度计要求压力增强的防范简单得多。
Sample handling occurs direct from the pressure canister or via pressure generator and is a much simpler method than the labor-intensive processes required by other high-pressure viscometers.
介绍了蔡恩粘度计的构造、操作、校正及其应用。
This article has described the structure, operation, calibration and application of Zahn viscometer.
介绍了蔡恩粘度计的构造、操作、校正及其应用。
This article has described the structure, operation, calibration and application of Zahn viscometer.