建立了一个微开关接触电阻模型。
A model of contact resistance for a microswitch is presented.
该方法能够实现接触电阻的定量测量。
This method can carry out the quantitative measurement of contact resistance.
另外,接触电阻对测试值有一定影响。
In addition, the contact resistance also influences the test value.
平均读数法去除了接触电阻的某些影响。
This average reading removes some of the effect of contact resistance.
对于干式开关,接触电阻与接触面积成反比关系。
For dry switches, the contact resistance is inversely related to the contact area.
通过四电极法测量了复合板与碳纸间的接触电阻。
The contact resistance between the composite plates and carbon paper were measured with a four-probe method.
电器触点间的接触电阻包括收缩电阻和薄膜电阻。
The contact resistance between contacts is composed of contraction resistance and velamen resistance.
接触电阻建模。
接触电阻一般非常小其范围在微欧姆到几个欧姆之间。
This resistance is normally very small, ranging from micro-ohms to a few ohms.
发现接触电阻的大小和稳定程度对测量结果有极大的影响。
It is found that the magnitude and stability of contact resistance greatly affect the measuring results.
这会导致接触电阻故障。关于该问题将会在本章随后讨论。
This causes contact resistance failures, which will be discussed later in this section.
引起电接点热故障原因多种多样,最终都导致接触电阻增加。
The heat fault of electrical contact, which results in the increase of contact resistance , can be caused by various origins.
图4 -42说明用来测试一个接点的接触电阻的基本配置。
Figure 4-42 illustrates a basic configuration for testing contact resistance of a contact.
本文以测量回路中的接触电阻为例,讨论微小电阻的测量方法。
We regard the contact electric resistance of measuring in the circuit as an example in the text, and discuss method of measurement of small electric resistance.
分析了粗糙度对电触头,尤其是轻负载用电触头接触电阻的影响。
Coarseness effects on contact resistance of electric contacts, especially, light_duty ones were analyzed.
我做的测试超小阻值的仪器,一般用来测试开关继电器的接触电阻!
I do ultra-small resistance test equipment, the general used to test the relay switch contact resistance!
讨论了氧化溶液组成和操作条件对氧化膜耐蚀性和接触电阻的影响。
Influences of solution component concentrations and working conditions on corrosion resistance and contact resistance of the film obtained are discussed.
微动接触电阻测试仪是用于微动过程中接触对电阻动态测试的装置。
The fretting contact resistance test machine is a dynamic test system to measure contact resistance during the fretting progress in contact pairs.
各种低阻测量的应用包括:接触电阻、超导体电阻和导体电阻率的测量等。
Low resistance measurement applications include contact resistance, superconductor resistance, and resistivity measurements of conductors.
利用以上测量方案我们对并五苯单晶材料的电阻率和接触电阻进行了测量。
We measured the resistance and the contact resistance of the pentacene by using such method.
导通电阻测试需注意参考点(基准点)选择、接触电阻及现场干扰的影响。
Conduction resistance test should take the effect of base point, contact resistance, and on-site disturbance into account.
分支接头结构合理并用先进的工艺制作,接触电阻极小,不受热胀冷缩影响。
Branch splice has less contact resistance and don't change with temperature because of its reasonable design and advanced process.
提出了材料表面接触电阻的测试方法,测试了几种典型材料的表面接触电阻;
The method is presented to test DC contact resistance of shielding materials' surface.
从理论和实验两方面讨论了接触电阻对导电混凝土测试电阻和电热效应的影响。
The influences of contact resistance on tested value of resistance and the electrothermal efficiency of electrically conductive concrete were discussed both in theory and experiment.
完成了导电环动态接触电阻测量系统的总体设计,包括硬件电路设计和软件设计。
The design of measuring system of dynamic contact resistance is achieved, including: hardware design and software design.
模压压力对接触电阻已有一定程度的影响,但其影响幅度不如接触压力和树脂含量那么大。
The compression pressure and temperature had a smaller influence on contact resistance compared with contacting pressure and PF content.
绝缘电阻、介质耐压和接触电阻检验是保证电连接器正常可靠地工作的最基本的常规检验项目。
The testing of insulation resistance, dielectrics voltage-resistance and contact resistance is essential for the connector to reliably operate.
用动态接触电阻测量系统进行了电磁继电器失效检测试验,监测了其触点闭合过程的接触压降。
The contacts voltage of counterpart contacts in the close course of electromagnetic relay is observed and recorded in its failure tests using dynamic contact resistance measurement system.
用动态接触电阻测量系统进行了电磁继电器失效检测试验,检测了其触点闭合过程的接触压降。
The contact voltage-drop of counterpart contacts in the closing course of electromagnetism relay is observed and recorded in its failure test using dynamic contact resistance measurement system.
用动态接触电阻测量系统进行了电磁继电器失效检测试验,检测了其触点闭合过程的接触压降。
The contact voltage-drop of counterpart contacts in the closing course of electromagnetism relay is observed and recorded in its failure test using dynamic contact resistance measurement system.
应用推荐